Immersed multilayer biodegradable ureteral stent with reformed biodegradation: An in vitro experiment

Author:

Yang Ganggang12,Xie Hua1,Huang Yichen1,Lv Yiqing1,Zhang Mingqing1,Shang Yafeng1,Zhou Junmei3,Wang Liping2,Wang Jin-Ye2,Chen Fang1

Affiliation:

1. Department of Urology, Shanghai Children's Hospital, Shanghai Jiao Tong University, Shanghai, China

2. School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China

3. Central Laboratory, Shanghai Children's Hospital, Shanghai Jiaotong University, Shanghai, China

Abstract

Objective The aim of this study was to develop a novel immersed multilayer biodegradable ureteral stent with reformed biodegradation and evaluate it in vitro. Methods Poly(glycolic-co-lactic acid) (PGLA), microsphere zein and BaSO4 were employed to produce a multilayer biodegradable stent using immersion technology. Tests of the biodegradable stents and conventional control stents were conducted in human urine in vitro to evaluate the biodegradable properties. The biocompatibility was assessed by the morphology and proliferation of urine-derived cells cultured with extracted media from the biodegradable stent and a latex material positive control. Results An immersed multilayer biodegradable stent was successfully produced. It began to degrade in week 2 and was fully degraded by week 4. The mass loss ratio in the first 2 weeks was low (approximately 10.0% at 1 week, 20.0% at 2 weeks) and increased after 3 weeks (approximately 70%) to the end of testing. During the first 2 weeks, the radial compression load performances of the biodegradable stents were better than those of the control stents with statistically significant differences ( p = 0.00, p = 0.01) and the tensile strengths were lower in the biodegradable stents than those in the control stents throughout the experiment. SEM showed that the stents degraded layer by layer from the outer to the inner wall. The influences on the cells of extracted medium from the biodegradable stents were morphologically slight and lower than 10% in relative growth rates. Conclusions This preliminary study demonstrates that the immersed multilayer biodegradable ureteral stent has good radial compression and biocompatible performance and can be degraded in vitro within 4 weeks in a moderate manner.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3