Analysis of Twenty-Two Performance Properties of Diesel, Gasoline, and Jet Fuels Using a Field-Portable Near-Infrared (NIR) Analyzer

Author:

Brouillette Carl1,Smith Wayne1,Shende Chetan1,Gladding Zack1,Farquharson Stuart1,Morris Robert E.2,Cramer Jeffrey A.2,Schmitigal Joel3

Affiliation:

1. Real-Time Analyzers Inc., Middletown, CT, USA

2. Naval Research Laboratory, Washington D.C., USA

3. US Army TARDEC, Warren, MI, USA

Abstract

The change in custody of fuel shipments at depots, pipelines, and ports could benefit from an analyzer that could rapidly verify that properties are within specifications. To meet this need, the design requirements for a fuel analyzer based on near-infrared (NIR) spectroscopy, such as spectral region and resolution, were examined. It was found that the 1000 to 1600 nm region, containing the second CH overtone and combination vibrational modes of hydrocarbons, provided the best near-infrared to fuel property correlations when path length was taken into account, whereas 4 cm−1 resolution provided only a modest improvement compared to 16 cm−1 resolution when four or more latent variables were used. Based on these results, a field-portable near-infrared fuel analyzer was built that employed an incandescent light source, sample compartment optics to hold 2 mL glass sample vials with ∼1 cm path length, a transmission grating, and a 256 channel InGaAs detector that measured the above stated wavelength range with 5–6 nm (∼32 cm−1) resolution. The analyzer produced high signal-to-noise ratio (SNR) spectra of samples in 5 s. Twenty-two property correlation models were developed for diesel, gasoline, and jet fuels with root mean squared error of correlation – cross-validated values that compared favorably to corresponding ASTM reproducibility values. The standard deviations of predicted properties for repeat measurements at 4, 24, and 38℃ were often better than ASTM documented repeatability values. The analyzer and diesel property models were tested by measuring seven diesel samples at a local ASTM certification laboratory. The standard deviations between the analyzer determined values and the ASTM measured values for these samples were generally better than the model root mean squared error of correlation—cross-validated values for each property.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3