Abstract

Background Lipaemic interference on automated analysers has been widely studied using soy-based emulsion such as Intralipid. Due to the greater adoption of fish oil-based lipid emulsion for total parenteral nutrition in view of improved clinical outcomes, we seek to characterize the optical properties of SMOFlipid 20% (Fresenius Kabi, Bad Homburg, Germany), a fish oil-based emulsion, on the Roche Cobas 6000 chemistry analyser (Roche Diagnostic, Basel, Switzerland). Method Various amounts of SMOFlipid were spiked into pooled serums. We plotted Roche Cobas Serum Index Gen.2 Lipaemia Index (L-index) against the amount of SMOFlipid added. We then studied the interference thresholds for aspartate aminotransferase, alanine aminotransferase, albumin and renal panel analytes using SMOFlipid. We subjected five levels of spiked lipaemia to high-speed centrifugation and analysed the specimens pre- and post-centrifugation. To postulate whether fish oil-based lipid emulsion interferes with laboratory results in the clinical setting, we calculated concentrations of SMOFlipid post-lipid rescue therapy and steady-state concentration of a typical total parenteral nutrition regime using pharmacokinetic principles. Results SMOFlipid optical behaviour is similar to Intralipid using the Serum Index Gen.2 L-index, with 1 mg/dL of SMOFlipid representing 1 unit of L-index. Manufacturer-stated interference thresholds are accurate for alanine aminotransferase, aspartate aminotransferase, albumin, urea and creatinine. High-speed centrifugation at 60 min 21,100 g facilitates the removal of fish oil-based SMOFlipid. Conclusion Based on the interference thresholds we verified and pharmacokinetics parameters provided by SMOFlipid manufacturer, total parenteral nutrition may not interfere with chemistry analytes given sufficient clearance, but lipid rescue therapy will interfere. Further studies assessing lipaemic interference on immunoassays are needed.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Artificially raised creatinine concentrations due to analytical interference for samples contaminated with total parenteral nutrition fluid;Annals of Clinical Biochemistry: International Journal of Laboratory Medicine;2023-07-11

2. Mechanisms underlying lipid emulsion resuscitation for drug toxicity: a narrative review;Korean Journal of Anesthesiology;2023-06-01

3. Methods to reduce lipemic interference in clinical chemistry tests: a systematic review and recommendations;Clinical Chemistry and Laboratory Medicine (CCLM);2021-11-15

4. Authors’ reply to ‘Plasma clearance and lipaemic index of lipid emulsion used for lipid emulsion treatment’;Annals of Clinical Biochemistry: International Journal of Laboratory Medicine;2021-04-12

5. Plasma clearance and lipaemic index of lipid emulsion used for lipid emulsion treatment;Annals of Clinical Biochemistry: International Journal of Laboratory Medicine;2021-02-01