A system for automated acquisition of digital flexion using a 3-D camera and custom gantry

Author:

Brogan David M1ORCID,Anaz Aws2ORCID,Skubic Marjorie2,Dy Christopher J1,Bridgeman Jay3

Affiliation:

1. Department of Orthopedic Surgery, Washington University in St. Louis, St Louis, MO, USA

2. Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO, USA

3. Department of Orthopedic Surgery, University of Missouri, Columbia, MO, USA

Abstract

Introduction Automated measurement of digital range of motion (ROM) may improve the accuracy of reporting and increase clinical efficiency. We hypothesize that a 3-D camera on a custom gantry will produce ROM measurements similar to those obtained with a manual goniometer. Methods A 3-D camera mounted on a custom gantry, was mechanized to rotate 200° around a platform. The video was processed to segment each digit and calculate joint angles in people with no history of any hand conditions or surgery to validate the system. A second-generation prototype was then assessed in people with different hand conditions. Metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joint flexion were measured repeatedly with a goniometer and the automated system. The average difference between manual and automatic measurements was calculated along with intraclass correlation coefficients (ICC). Results In the initial validation, 1,488 manual and 1,488 automated joint measurements were obtained and the measurement algorithm was refined. In people with hand conditions, 688 manual and 688 automated joint measurements were compared. Average acquisition time was 7 s per hand, with an additional 2–3 s required for data processing. ICC between manual and automated data in the clinical study ranged from 0.65 to 0.85 for the MCP joints, and 0.22 to 0.66 for PIP joints. Discussion The automated system resulted in rapid data acquisition, with reliability varying by type of joint and location. It has the potential to improve efficiency in the collection of physical exam findings. Further developments of the system are needed to measure thumb and distal phalangeal motions.

Funder

Wallace H. Coulter Foundation

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3