Affiliation:
1. Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
Abstract
Objective The long-term preservation of residual hearing after cochlear implantation has become a major goal over the past few years. The aim of the present study was to evaluate residual hearing in the long-term follow-up using mid-scala electrodes. Methods In this retrospective, single-center study, we collected data from 27 patients who were implanted between 2014 and 2015 with residual hearing in the low-frequency range using a mid-scala electrode. Measurements of the hearing thresholds were carried out directly postoperatively (day 1 after surgery) and in the long-term follow-up 43.7 ± 6.9 months. The calculation of the extent of audiological hearing preservation was determined using the HEARRING group formula by Skarsynski. Results Postoperative preservation of residual hearing was achieved in 69.2% of the cases in the low-frequency range between 250 Hz and 1 kHz, of which 89.5% of the patients had frequencies that suggested using electroacoustic stimulation (EAS). In the long-term follow-up, 30.8% of the patients showed residual hearing; however, 57.1% had apparently benefited from EAS. Conclusion Preservation of residual hearing is feasible in the long term using mid-scala electrodes. Postoperatively, there is over the half of patients who benefit from an EAS strategy. The long-term follow-up shows a certain decrease in residual hearing. However, these results are comparable to studies relating to other types of electrodes. Further research should be conducted in future to better evaluate hearing loss in long-term follow-up, compared to direct postoperative audiological results.