Evaluation of the Hemodynamic Performance of St.Jude Mitral Prostheses: A Pilot Study by Dobutamine-Stress Doppler Echocardiography

Author:

Rezaian Gholam Reza1,Aghasadeghi Kamran1,Kojuri Javad1

Affiliation:

1. Department of Medicine (Cardiology), Shiraz University of Medical Sciences, Shiraz, Iran

Abstract

In contrast to the widespread use of dobutamine stress Doppler echocardiography in the hemodynamic evaluation of the prosthetic valves in aortic position, it has been rarely, if ever, used for assessment of these valves in mitral position. Therefore, this pilot study was done to assess the hemodynamic performance of St. Jude prosthetic mitral valves (functional orifice area 25-31) with dobutamine-stress Doppler echocardiography. Twenty consecutive patients (13 women and 7 men, aged 23 to 42 years) who had undergone mitral valve replacement 6 to 4745 days previously and 16 healthy volunteers (5 women and 11 men, aged 18 to 42 years) underwent dobutamine-stress Doppler echocardiography. Dobutamine infusion was started at a rate of 5 µg/kg per minute and was increased by 5 µg increments at 3-minute intervals. Maximum and mean gradients as well as pressure halftime were measured at rest and at the end of each stage. The correlation between Doppler-derived variables versus the heart rate was assessed and a regression equation was obtained for each of them. A significant increase in blood pressure, heart rate, maximum and mean gradients was noted during dobutamine infusion in both groups. There was a significant positive linear correlation between the increasing transprosthetic mitral valvular maximum and mean gradients and the increments in the heart rate (Gmax = 4.47+ 0.093 [HR], r=0.474, p<0.05) and (Gmean = 3.0+0.003 [HR], r=0.2697, p<0.05), respectively, indicating the heart rate dependency of these parameters. Pressure halftime, on the other hand, had an inverse but linear relationship with the heart rate (PHT= 142 - 0.55 [HR], r=-0.577, p<0.05). Similar findings were found for the control group as well. Standard dobutamine-stress echocardiography can safely be performed in patients with St. Jude mitral valve prostheses. Single Doppler measurements of the pressure gradients and pressure halftime may yield erroneous conclusions regarding the function and size of these valves unless corrected for the patients simultaneous, online heart rate. The use of the regression equations obtained in this pilot study may help to partly overcome some of these difficult issues.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3