A Rheolytic System for Percutaneous Coronary and Peripheral Plaque Removal

Author:

Drasler William J.1,Jenson Mark L.1,Wilson Gregory J.1,Thielen Joseph M.1,Protonotarios Emmanuil I.1,Dutcher Robert G.1,Possis Zinon C.1

Affiliation:

1. Possis Medical, Inc., Minneapolis, Minnesota

Abstract

A method for plaque dissolution has been identified that percutaneously delivers a pulsatile high-velocity stream of saline to the site of an atheromatous lesion within a coronary or peripheral artery. In vitro evaluation and in vivo canine and porcine testing were performed using this 'rheolytic' system to deter mine its feasibility in ablating calcified plaque and soft thrombotic tissue. A prototype rheolytic guidewire capable of providing 30,000 psi of internal pressure was designed to fit within the guidewire lumen of a standard percutane ous transluminal coronary angioplasty catheter. An additional over-the-wire rheolytic catheter was fabricated to follow a standard .014-inch guidewire. The rheolytic devices were tested in vitro with simulated atheromatous and thrombotic lesions to evaluate the size and quantity of the particulate effluent. The particulate was then sterilized, mixed with saline, and introduced percutaneously into the animal kidney and heart for evaluation. The in vitro studies demonstrated that the rheolytic catheter and guidewire were able to follow both a coronary and femoral arterial model and successfully ablate the simulated lesions. The particle size for osseous, muscular, and car tilagenous tissue. ranged from 2 to 6 micrometers; for fresh human plaque the particles ranged from 2 to 15 micrometers. Injection of cartilagenous and plaque particles into the animal model caused very slight regions of necrosis but no clinical sequelae . Applications of the rheolytic devices to the animal femoral artery demonstrated that both devices could ablate and cross calified or soft thrombosed lesions without damage to the vessel wall; the rheolytic catheter provided a debulking of the plaque. The ability to cut through calcified and soft lesions with the rheolytic devices without thermal damage may provide this system with advantages over current atherectomy methods. Its flexibility suggests that it may have applications in the coronary position.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine

Reference17 articles.

1. Hayden WG: Historical background of balloon angioplasty. In: Endovascular Surgery, ed. by Moore WS, Ahn SS. Philadelphia: WB Saunders, 1989, pp 131-140.

2. Initial results of laser recanalization in lower extremity arterial reconstruction

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Rheolytic Thrombectomy of Acute Stent Thrombosis of Cervical Vertebral Artery;Interventional Neuroradiology;2002-09

2. Clinical application of a new rheolytic thrombectomy catheter system for massive pulmonary embolism;Catheterization and Cardiovascular Interventions;1999-05

3. Experimental Treatment of Early Chronic Iliac Vein Thrombosis with a Modified Hydrodynamic Thrombectomy Catheter: Preliminary Animal Experience;Journal of Vascular and Interventional Radiology;1999-01

4. Update on Extractional Thrombectomy Catheter, AngioJet?;Journal of Interventional Cardiology;1998-10

5. Perkutane Thrombektomie und mechanische Thrombolyse;RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren;1998-10