Changes in Hemodynamics Due to the Contrast Medium During Left Ventriculography

Author:

Koeda Toshihiko1,Motegi Itaru1,Ichikawa Takashi1,Suzuki Tomoyuki1,Kato Masataka1

Affiliation:

1. 2nd Department of Internal Medicine, Iwate Medical University School of Medicine, Morioka, Japan

Abstract

Seventeen patients with heart diseases examined by left ventricular angiography were divided into two groups consisting of those with a clinical history of heart failure (CHF+) and those without (CHF-). Changes in hemodynamics, circulating blood volume, and plasma volume due to injection of the contrast medium were studied, and the following results were obtained. Both the CHF - and CHF + groups showed an increase in heart rate after injection of the contrast medium, but a statistically significant difference (p < 0.05) was noted only at one and two minutes after angiography in both groups. Left ventricular systolic pressure decreased after injection of the contrast medium in both groups, but the CHF+ group required a longer time for recovery. In the CHF - group, the left ventricular end-diastolic pressure increased slightly after injection of the contrast medium, but in the CHF+ group it increased markedly with a statistically significant difference (p < 0.01). Stroke volume, measured by a noninvasive, continuous cardiac output monitor according to the impedance method, increased upon injection of the contrast medium in the CHF— group. However, in the CHF+ group it decreased, although no statistically significant difference was noted in either group. Cardiac index increased markedly upon injection of the contrast medium in the CHF— group with a statistically significant difference (p < 0.01), but hardly any change was observed in the CHF+ group. Circulating blood volume increased in both groups ten minutes after injection of the contrast medium, but whereas the CHF - group showed no statistically significant increase and had a gradual reduction to the original state an hour afterward, a statistically significant increase over original values in the CHF+ group was observed at ten minutes and one hour after injection. The mean value of the CHF+ group was statistically significantly higher than that of the CHF- group at one hour after injection. Circulating plasma volume showed statistically significant mean increases over original values in both groups at ten minutes and at one hour after injection of the contrast medium. The mean value of the CHF+ group was statistically significantly higher than that of the CHF- group at one hour after injection. In conclusion, patients with heart failure, in comparison with those without, showed different changes in hemodynamics, circulating blood, and plasma volumes caused by the contrast medium, and thus it was necessary to be cautious when the contrast medium was injected into patients with a history of heart failure.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine

Reference13 articles.

1. Verel D., Grainger RG: Cardiac Catheterization and Angiography. Edinburgh and London: Livingstone, 1969, p 32.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3