Incidence and predictors of mismatch after mechanical mitral valve replacement

Author:

El Midany Ashraf AH1ORCID,Mostafa Ezzeldin A1ORCID,Hikal Tamer1,Elbarbary Mostafa G1,Doghish Ayman1,Khorshid Ramy1ORCID,Abdelgawad Basem M2ORCID,Sharaa Mohamed3,El-Sokkary Ismail N3,Hossiny Mohamed El3,Abdelmoaty Haytham3,Elkhonezy Bahaa A3

Affiliation:

1. Department of Cardiovascular & Thoracic Surgery, Ain-Shams University Hospital, Faculty of Medicine, Cairo, Egypt

2. Department of Cardiovascular & Thoracic Surgery, Faculty of Medicine, Banha University, Banha, Egypt

3. Department of Cardiovascular & Thoracic Surgery, Faculty of Medicine, Al-Azhar University, Cairo, Egypt

Abstract

Background Patient-prosthesis mismatch after mitral valve replacement has an unfavorable postoperative hemodynamic outcome, which underlines the importance of identifying and preventing prosthesis- and patient-related risk factors. This study was conducted to determine the incidence and identify possible predictors of patient-prosthesis mismatch. Methods A prospective study was conducted on 715 patients with a mean age of 42 ± 11 years who underwent mechanical mitral valve replacement between 2013 and 2017. The effective orifice area of the prostheses was estimated by the continuity equation, and a mismatch was defined as an effective orifice area index ≤1.2 cm2·m−2. The mean clinical and echocardiographic follow-up was 26.74 ± 11.58 months. Multivariate regression analysis was performed to identify predictors of patient-prosthesis mismatch. Results Patient-prosthesis mismatch was detected in 382 (53.4%) patients. A small mechanical prosthesis (<27 mm) was inserted in 54.3%. Mortality during follow-up was 9% (65 patients). Patient-prosthesis mismatch was identified in patients with preoperative rheumatic mitral valve pathology, associated tricuspid regurgitation, higher New York Heart Association class, preoperative atrial fibrillation, mitral stenosis, and small preoperative left ventricular dimensions. Multivariate analysis identified mitral stenosis, preoperative atrial fibrillation, and small postoperative left ventricular end-diastolic dimension as risk factors for patient-prosthesis mismatch. Conclusion Patient-prosthesis mismatch is a common sequela after mechanical mitral valve replacement. Identification of predictors of patient-prosthesis mismatch can help so that a preoperative strategy can be implemented to avoid its occurrence.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Pulmonary and Respiratory Medicine,General Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3