Affiliation:
1. Department of Thoracic and Cardiovascular Surgery, Heart Centre North Rhine-Westfalia, Bad Oeynhausen, University of Bochum, Germany
Abstract
Thirty male patients undergoing coronary artery bypass grafting were divided into two groups, group receiving pulsatile perfusion, group II nonpulsatile perfusion. A double roller pump system for extracorporeal circulation was employed. Intra- and postoperative fluid balances and bodyweight gains were controlled under clinical conditions. There were no significant differences between the groups with regard to clinical data, operative procedure, perfusion parameters, drug treatment or intensive care treatment. The intra-operative mean fluid balance of group I was 794.0ml (66%) lower than that of group II, while the balance 24 hours postoperatively was 136.7ml (37%) lower in group I. Thus, the total mean fluid balance for the pulsatile group was 931.0ml (59%) lower than the nonpulsatile group, in accordance with the bodyweights, which showed a 954.0g (63%) lower outcome in the pulsatile group. Less supplementary volume and higher urine production were the main factors. It appears that volume saved during pulsatile ECC need not be replaced postoperatively. These findings indicate that pulsatile perfusion leads to diminished fluid overloading, which could be an important advantage, especially for high-risk patients.
Subject
Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Safety Research,Radiology Nuclear Medicine and imaging,General Medicine
Cited by
11 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献