In its simplest form, a Closed Cavity Façade (CCF) consists of a double or triple glazing unit (DGU or TGU) on the inner layer and single glazing on the outer one, forming a sealed non-ventilated cavity with an automated shading device in between. Given its dynamic behaviour, this technology can dynamically control the flow of solar energy and light penetrating the building. Using EnergyPlus and IDA ICE, several CCF configurations were investigated and compared to the baseline (TGU). MATELab, an office-like test facility at the University of Cambridge, was used as the model, which was beforehand experimentally validated. The results show extensive benefits of CCFs compared to traditional TGU systems, in terms of thermal performance and occupants’ comfort. The CCF configurations investigated led to an improvement of energy performance in the range of 18–37% compared to the traditional TGU, depending on the CCF configuration and the climate while a previous study, using CCF configurations with DGU as inner skin, revealed an improvement of energy performance in the range of 22–41% compared to the conventional DGU. Further investigation showed that glass coatings and solar shading characteristics play an important role in cutting down overheating phenomenon while increasing occupants’ comfort. Practical application: Governments are making ever more stringent energy regulations for the building industry aiming to reduce energy consumption and carbon emissions. At the same time, building owners and architects are looking at cost-effective solutions for the long-term performance of buildings while tenants/occupants are more than ever aware of the fact that building comfort increases well-being and productivity. In all these regards, this work focuses and accentuates that substantial improvements can be achieved by designing and using suitable configurations of the innovative Closed Cavity Façade according to the climatic conditions of each location. The results presented indicate that there is much potential in improving the energy and comfort performance of a building, raising awareness to help deploy innovative glazing technologies.

Publisher

SAGE Publications

Subject

Building and Construction

Reference36 articles.

1. Report-environment/indoor-air-quality

2. U.S. Environmental Protection Agency (EPA), Viewed date: 30 January 2021, https://www.epa.gov/report-environment/indoor-air-quality

3. IEA and UNEP. 2019. Global Status Report for Buildings and Construction, Vol. 224. UN Enviroment programme, 2019, p. 41, https://wedocs.unep.org/bitstream/handle/20.500.11822/30950/2019. GSR.pdf? 41 p.

4. European Commission - Press Commission. Commission welcomes final vote on energy performance of buildings, 2017, p. 19, http://europa.eu/rapid/press-release_IP-18-3374_en.htm.