Abstract

We report on the perceived comfort data collected while ten female subjects exercised in the hot, humid environment ( 29.4°C, 75% RH) wearing garments made from the three experimental knit fabrics. These findings are related to the fabric thermophys iological comfort data reported in Part I, the mechanical and surface related comfort data in Part II, and the skin alteration data in Part III of this series. At four times during the wear protocol (after acclimation, after 10 minutes of wear, after 40 minutes of exercise, and after 20 minutes of rest following exercise), subjects were asked to indicate overall comfort and thermal, wetness, and contact sensations. There was no difference between the fabrics for wetness or thermal sensation, a result explainable in terms of the extremely small differences in water and heat transport data reported in Part I. The thermal insulation, permeability index, and comfort limit values we calculated predict that differences in perceived thermal and wetness sensation should be minimal. Skin temperature was a significant determinant of perceived thermal comfort in our regression model, but capillary blood flow was not. The regression model for wetness sensation showed that stratum corneum water content and evaporative water loss were statistically significant determinants. Use of wetness-related and contact sensation descriptors differed for the three experimental fabrics. Differences in the wetness-related descriptors appear related to the percent water uptake of the fabrics during exercise. Fiber denier and fabric mechanical and surface feature data were useful in explaining the difference in contact sensations. The fabrics differed in perceived overall comfort. In the regression analysis, capillary blood flow was the only physio logical factor with a statistically significant effect on overall comfort. We suspect a link between the mechanical and surface features and capillary blood flow.

Publisher

SAGE Publications

Subject

Polymers and Plastics,Chemical Engineering (miscellaneous)

Cited by 35 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3