Affiliation:
1. Civil Engineering College, RC&PC Key Laboratory of Education Ministry, Southeast University, Nanjing 210096, China,
Abstract
Viscoelastic (VE) dampers are one of the most common earthquake mitigation devices. This paper addresses the mathematical modelling of VE dampers and the dynamic analysis of structures with VE dampers. In this paper, the equivalent standard solid model, a new mathematical model of VE dampers, is used to describe the influence of temperature on the energy absorption features of VE dampers. Elastoplastic time field analysis, frequency field analysis and shaking table tests are used to analyze responses of a 1/5 scale three-story reinforced concrete frame structure with and without VE dampers. Comparisons between the numerical and experimental results show that the VE dampers can be modeled by the equivalent standard solid model and that the VE dampers are effective in reducing the seismic responses of structures.
Subject
Mechanical Engineering,Mechanics of Materials,Aerospace Engineering,Automotive Engineering,General Materials Science
Cited by
102 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献