New Biparietal Bipolar Catheter Prototype for Hybrid Atrial Fibrillation Ablation

Author:

Matteucci Francesco1,Maesen Bart12ORCID,De Asmundis Carlo3,Parise Gianmarco1,Micali Linda Renata1,Tuijthof Gabrielle4,Gerits Peter5,Vernooy Kevin2,Maessen Jos G.12,La Meir Mark13,Gelsomino Sandro13ORCID

Affiliation:

1. Cardiovascular Research Institute Maastricht - CARIM, Maastricht University Medical Center, Maastricht, The Netherlands

2. Cardiothoracic Department, Maastricht University Hospital, Maastricht, The Netherlands

3. Cardiothoracic Department, Brussels University Hospital, Brussels, Belgium

4. IDEE Engineering, Maastricht University, Maastricht, The Netherlands

5. Maastricht Instruments BV, Maastricht, The Netherlands

Abstract

Objective To evaluate the size and depth of linear lesions by in vitro testing with a custom-made radio frequency biparietal bipolar ablation catheter in a single-stage setting. Methods A custom-made catheter was created to generate linear lesions around the left atrium and pulmonary veins of an ex vivo pig. Two frames were made, 1 epicardial and 1 endocardial. A continuous copper braid electrode and an alignment system consisting of 2 parallel rows of neodymium magnets were embedded in a flexible plastic support. After 24 hours of formalin conservation, samples of the left atrium of a freshly slaughtered pig were sliced in a cryotome, thus obtaining a sequence of 100-µm thick layers extending from the endocardial to the epicardial side. After being digitized through a scanner, these layers were evaluated using morphometric computer software. For each slice, we evaluated the maximum length of the lesions, the maximum epicardial length, the maximum endocardial length, the total area of the lesion, and the total volume. Results Forty transmural lesions from 40 specimens were obtained. The results were the following (the number in parenthesis is the interquartile range in mm): lesion maximum length ( L MAX) was 7.297 mm (0.006), epicardial maximum length ( L EPI) was 7.291 mm (0.014), and endocardial maximum length was 7.291 mm (0.018). The total area and total volume were 1018.50 ± 36.51 mm2 and 101.85 ± 3.65 mm3, respectively. Conclusions Our prototype showed very promising results. The next step will be to enhance the design for clinical application.

Funder

Triton Fundation

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3