Electrophysiologic Evaluation of the Facial Nerve and Blink Reflex Pathways in Asymptomatic Cochlear Implant Users

Author:

Edizer Deniz Tuna1,Adatepe Turgut2,Uzun Nurten3,Yigit Ozgur1,Gunduz Aysegul3,Yildiz Muhammet1,Celebi Ozlem Onerci1

Affiliation:

1. Istanbul Training and Research Hospital, Otorhinolaryngology Department, Istanbul, Turkey

2. Istanbul Training and Research Hospital, Electrophysiology Laboratory, Istanbul, Turkey

3. Cerrahpasa Medical Faculty, Neurology Department, Istanbul University, Istanbul, Turkey

Abstract

Objective To evaluate the functional integrity of the facial nerve and blink reflex (BR) pathways in asymptomatic patients who underwent cochlear implantation (CI). Study Design Case series with planned data collection. Setting Tertiary referral center. Subjects and Methods Twenty-four deafened patients with unilateral CI who had no complications were enrolled. Bilateral compound muscle action potentials (CMAPs) of the facial nerve were recorded over the nasalis and occipitalis muscles, whereas BR responses were recorded over the orbicularis oculi after supraorbital nerve stimulation. All recordings were performed when the external part of the implant was in place (CIp) and after its removal (CIr), except occipitalis recordings, which were performed only after removal. The amplitude and latency of CMAP were measured to evaluate the axonal integrity of the zygomatic and posterior branches of the facial nerve. Latency, amplitude, and duration of the BR were measured to investigate the integrity of trigeminofacial connections. Results The amplitude and latency of CMAP over the nasalis muscle were bilaterally normal, and the difference between CIp and CIr was not statistically significant. No CMAP of the occipitalis muscle was recorded in 4 (16.7%) patients, and low-amplitude responses were recorded on the implant side of 20 (83.3%). Amplitudes of the contralateral R2 response were higher in the CIp condition versus the CIr condition ( P = .031). There were no differences among other BR components. Conclusion During functioning of the CI system, excitability of the facial circuit may increase either through the facial motor nucleus or through removal of the inhibitory effect of the descending pathway.

Publisher

SAGE Publications

Subject

Otorhinolaryngology,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3