Evaluation of the performance of two new generation pulse oximeters in cats at different probe positions and under the influence of vasoconstriction

Author:

Dörfelt René1ORCID,Diels Julia1,Hartmann Katrin1

Affiliation:

1. Clinic of Small Animal Medicine, Centre for Clinical Veterinary Medicine, Faculty of Veterinary Medicine, Ludwig-Maximilians-University, Munich, Germany

Abstract

Objectives The aim of this study was to compare the failure rate of two new generation pulse oximeters at different probe positions, and with and without vasoconstriction, in anaesthetised cats. Methods This prospective clinical study included 103 cats in which the new generation pulse oximeters, the Rad-5 (Masimo) and EDAN H100N (EDAN), were evaluated. Premedication consisted of the vasoconstrictive drug combination butorphanol (0.2 mg/kg IV) and dexmedetomidine (5 µg/kg IV), or butorphanol only (0.2 mg/kg IV). Pulse oximeter failure rate at the tongue was compared between both groups. Pulse oximeter failure rate was also analysed at the alternative probe positions of the lip, pinna, knee fold and toe in the butorphanol group. Student’s t-test, Wilcoxon matched pairs signed rank test, Mann−Whitney U-test, Friedman test and χ2 test were performed. A P value <0.05 was considered to be statistically significant. Results Overall failure to achieve an adequate signal was 37.6% with the Masimo and 48.0% with the EDAN pulse oximeter ( P <0.0001). At the standard probe position on the tongue, the Masimo failed in 4.5%, while the EDAN failed in 35.3% ( P <0.0001). Vasoactive premedication increased the failure rate for the Masimo from 3.8% to 5.2% ( P = 0.3414) and for the EDAN from 22.4% to 49.0% ( P <0.0001). At the alternative probe positions of the lip and knee fold, failure rates for the Masimo were lower (39.7% and 81.4%) than with the EDAN (52.6% and 94.4%; P = 0.0231 and P = 0.0005, respectively), while the Masimo failed more often at the pinna (63.5%) than the EDAN (47.4%; P = 0.0044). At the alternative probe position of the toe, the failure rate for the Masimo (32.7%) was not different from the EDAN (38.5%; P = 0.7547). Conclusions and relevance The Masimo pulse oximeter had lower signal failure rates at the standard probe position on the tongue and at 2/4 alternative probe positions. The standard probe position on the tongue had the lowest failure rate for both devices. Dexmedetomidine-induced vasoconstriction increased the failure rate for the EDAN but not for the Masimo pulse oximeter.

Publisher

SAGE Publications

Subject

Small Animals

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3