Validation of a biomechanical testing protocol of craniodorsal hip luxation in feline cadavers and comparison of two ultra-high molecular weight polyethylene materials used for extra-articular hip stabilisation

Author:

Letesson Julien1,Goin Bastien23ORCID,Viguier Eric2,Cachon Thibaut2

Affiliation:

1. Lameilhé Veterinary Clinic, Castres, France

2. University of Lyon, VetAgro Sup, Interactions Cellules Environnement (ICE), Marcy l’Etoile, France

3. Novetech Surgery, Monaco

Abstract

Objectives The aim of our study was to describe a biomechanical testing protocol to reproduce ex vivo craniodorsal hip luxation specific to the feline model, and evaluate the biomechanical properties of an intact hip joint compared with the fixation strength of two different techniques of extra-articular hip stabilisation. Methods Eighteen hip joints (femur and hemipelvis) were harvested from nine mature feline cadavers. CT was performed for each hip joint so that a biomechanical base specific to each joint morphotype could be created using computer-aided design. The biomechanical bases were then produced using a three-dimensional printer to secure the hip joints during testing. A total of 34 biomechanical compression tests were performed. Eighteen compression tests were performed in the control group, of which two fractured. The remaining 16 hip joints were then randomly assigned either to group A (hip joints stabilised with an extra-articular ultra-high molecular weight polyethylene (UHMWPE) implant secured by an interference screw [n = 8]) or to group B (hip joints stabilised with a UHMWPE iliofemoral suture [n = 8]). Results Mean ± SD yield, failure load and linear stiffness in the control group were 616 ± 168 N, 666 ± 158 N and 231 ± 50 N/mm, respectively. The relative fixation strength (% of intact joint) before hip luxation in groups A and B was 43.8% and 34.7%, respectively. No statistical difference was found between groups A and B for yield and failure load. However, the reoccurrence of craniodorsal hip luxation was higher in group B than in group A, in 5/8 and 0/8 tests, respectively. Moreover, in group A, the extra-articular UHMWPE implant induced caudodorsal hip luxation, reported as failure mode in 7/8 cases. Conclusions and relevance This modified biomechanical protocol for testing craniodorsal hip luxation in a feline model was validated as repeatable and with acceptable variance. The extra-articular UHMWPE implant stabilisation technique proved to be more efficient in avoiding reoccurrence of craniodorsal hip luxation than UHMWPE iliofemoral suture.

Funder

Novetech Surgery

Publisher

SAGE Publications

Subject

Small Animals

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3