Experimental investigation of the ease allowance of clothing and thermal-moisture comfort in exercise based on fuzzy comprehensive evaluation

Author:

Zhang Jun12ORCID,Tong Mengxia1,Zhang Mengyun13,Zhang Yating4,Jiang Xuewei1ORCID,Zhu Xiaoxiao5,Guo Mengna1

Affiliation:

1. School of Fashion, Wuhan Textile University, Wuhan, Hubei, China

2. Hubei Key Laboratory of Digital Textile Equipment, Wuhan, Hubei, China

3. École Nationale Supérieure des Arts et Industries Textiles/Génie et Matériaux Textiles Laboratory (ENSAIT/GEMTEX), Roubaix, France

4. College of Fashion and Design, Donghua University, Shanghai, China

5. School of Fashion, Beijing Institute of Fashion Technology, Beijing, China

Abstract

The level of thermal-moisture comfort experienced by an individual is strongly influenced by the clothing they wear and also influenced by the ease allowance of that clothing. This study aimed to investigate the impact of ease allowances of clothing on thermal-moisture comfort during exercise or movement. Seventeen female subjects were asked to wear sample clothing with different sizes during a designated 5-phase exercise in a climate chamber. Throughout the exercise phases, the temperature and humidity of the microclimate under the clothing were monitored while the subjects provided subjective evaluations of their comfort levels. To account for variation in ease allowances, the 32 experimental repetitions were grouped based on the ease allowance of the clothing worn. The FCE-CRITIC method was then used to determine the variable weights of factors and to compare the thermal-moisture status to the subjective evaluation. Results revealed that humidity was more strongly weighted during RS and RC (i.e., running and recovery phase after exercise) compared to other phases, means that moisture comfort was the main factor driving the clothing comfort sensation within the two phases. The ease allowance of clothing was found to have an impact on the sensations of thermal and moisture comfort during exercise, although this effect was not significant. Furthermore, the study identified the optimum range of ease allowance for thermal-moisture comfort during exercise to be between 6 and 10 cm.

Funder

The Graduate Innovation Fund Project of Wuhan Textile University

Hubei Key Laboratory of Digital Textile Equipment, Wuhan Textile University

R&D Program of Beijing Municipal Education Commission

Wuhan Textile and Apparel Digital Engineering Technology Research Center

Publisher

SAGE Publications

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献