MRI after successful eyeWatchTM implantation

Author:

Roy Sylvain12ORCID,Villamarin Adan1,Stergiopulos Nikolaos1ORCID,Mermoud André2

Affiliation:

1. Swiss Federal Institute of Technology, Lausanne, Switzerland

2. Swiss Visio, Montchoisi Clinic, Lausanne, Switzerland

Abstract

The eyeWatchTM is a new glaucoma drainage device that includes an adjustable mechanism that can vary the resistance to aqueous humor outflow during the postoperative period to reduce the burden of postoperative intraocular pressure (IOP) management. The mechanism contains a magnetic rotor that can be adjusted using an external magnetic control unit. Adjustments of the position of the rotor are performed mostly in the initial postoperative follow-up period in order to reach the target IOP. However, for some patients, it might be necessary to perform MRI for the sake of medical investigations. As the MRI is creating a strong magnetic field, this magnetic field is likely to interact with the adjustable rotor of the eyeWatchTM, resulting in modification of the IOP. We report the case of an 82-old female patient successfully operated with the implantation of an eyeWatchTM. The patient underwent a cerebral MRI for persistent headache. Shortly after the MRI procedure, the patient was checked at the eye clinic to assess the position of the rotor and to measure the IOP. The eyeWatchTM was readjusted to the former position set before undergoing the MRI. No complications were reported in the follow-up after MRI. This case demonstrates that MRI examinations can be safely performed after glaucoma surgery using an eyeWatchTM without compromising on the quality of the imaging or the stability of the IOP. This is a complication-free procedure that only requires checking the new position of the rotor and re-adjusting the implant, if necessary, to achieve the target IOP.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Klinische Ergebnisse des eyeWatch-Systems: 1-Jahres-Outcome;Die Ophthalmologie;2024-02-16

2. Development and material characteristics of glaucoma surgical implants;Advances in Ophthalmology Practice and Research;2023-11

3. Eyewatch adjustable drainage device in vitrectomized eyes with refractory glaucoma;European Journal of Ophthalmology;2023-07-12

4. Comparison of glaucoma drainage implants;Die Ophthalmologie;2023-04

5. Adjustable drainage devices;The Science of Glaucoma Management;2023