Microincision cataract surgery with implantation of a bitoric intraocular lens using an enhanced program for intraocular lens power calculation

Author:

Lesieur Gilles1ORCID

Affiliation:

1. Centre Ophtalmologique IRIDIS, Albi, France

Abstract

Purpose: To evaluate the potential benefit of a new version of an online toric intraocular lens calculator in eyes implanted with a bitoric intraocular lens. Patients and methods: Retrospective observational comparative study in patients that underwent cataract surgery with implantation of the bitoric intraocular lens AT TORBI 709M (Carl Zeiss Meditec AG, Jena, Germany). Visual and refractive outcomes were evaluated at 1 month after surgery. The selection of the toric intraocular lens power was performed with the software Z CALC 2.0 (Carl Zeiss Meditec AG). The absolute refractive prediction errors for the spherical equivalent and cylinder were calculated and compared with the values that would have been obtained using version 1.5 of the same software. Results: A total of 393 eyes of 276 patients were evaluated. Mean postoperative sphere and cylinder were +0.03 ± 0.54 and −0.19 ± 0.30 D, respectively. A total of 95.67%, 98.22%, and 95.17% of eyes had a postoperative sphere, cylinder, and spherical equivalent within ±1.00 D, respectively. Mean absolute refractive prediction error for spherical equivalent was 0.34 ± 0.27 D with the two versions of the Z CALC software. In contrast, a significantly higher absolute refractive prediction error value for the cylinder was found with Z CALC 1.5 compared to version 2.0 (0.35 ± 0.32 vs 0.28 ± 0.30 D, p < 0.001). The absolute refractive prediction error for cylinder was ⩽0.25 D in 62.3% and 47.5% when using the versions 2.0 and 1.5, respectively. Conclusion: The use of an optimized software for toric intraocular lens power calculation, considering the contribution of posterior corneal astigmatism, improved the astigmatic outcome with a bitoric intraocular lens.

Funder

Carl Zeiss Meditec AG

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3