Accuracy of the indices of MS-39 anterior segment optical coherence tomography in the diagnosis of keratoconic corneas

Author:

Elkitkat Rania S12ORCID,Rifay Yasser3,Gharieb Hesham M4ORCID,Ziada Hossam Eldin A5

Affiliation:

1. Assistant Professor of Ophthalmology, Faculty of Medicine, Ain Shams University, Cairo, Egypt

2. Watany Research and Development Center, Cairo, Egypt

3. Consultant of Ophthalmology, Dr Rifay Ophthalmology Center, Rabat, Morocco

4. Lecturer of Ophthalmology, Faculty of Medicine, Ain Shams University, Cairo, Egypt

5. Assistant Professor of Ophthalmology, Al Azhar University, Cairo, Egypt

Abstract

Purpose To determine the normative and the cut-off values of various indices available in the MS 39 Anterior Segment Optical Coherence Tomography (MS-39 AS-OCT) for keratoconus (KC) diagnosis, and to detect the accuracy of the variable available parameters. Methods This cross sectional observational study was conducted at Dr Rifay Ophthalmology Center, Rabat, Morocco, on 172 eyes with KC (group 1) and 248 eyes of healthy controls (group 2). Participants were screened using MS-39 AS-OCT (CSO, Firenze, Italy). The investigated indices included: keratometric indices, pachymetric indices, elevation indices, Keratoconus Summary Indices (KSI), aberration indices, and epithelial mapping evaluation. Results Most of the studied indices were significantly different between both groups (P value <0.001). Twenty two indices had Area Under the Receiver Operating Curve (AUROC) values >0.950, eight of which were from the KSI. The indices with the highest AUROC values were: Root Mean Square (RMS) for the front corneal surface at 6 mm circle (AUROC = 0.996, and best cut-off >1.69 with sensitivity of 97.67% and specificity of 97.98%) and RMS per unit of area for the front surface at 6 mm circle (AUROC = 0.996, and best cut-off >0.06 with sensitivity of 97.67% and specificity of 97.98%). Epithelial thickness-derived metrics were not among the parameters with the highest accuracy. Conclusions This study presented the mean and the cut-off values for a plethora of parameters available in the MS-39 AS-OCT. The results of this study show that MS-39 AS-OCT is a valuable equipment for diagnosing keratoconic corneas, with a high accuracy detected for many parameters.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3