Removing residual cortical material during cataract surgery: Visco polishing and the grindstone effect as a new surgical technique

Author:

Borkenstein Andreas F1ORCID,Borkenstein Eva-Maria1,Malyugin Boris23ORCID

Affiliation:

1. Privatklinik der Kreuzschwestern Graz, Borkenstein & Borkenstein Private Practice, Graz, Austria

2. S. Fyodorov Eye Microsurgery Federal State Institution, Moscow, Russian Federation

3. A. Yevdokimov Moscow State University of Medicine and Dentistry, Moscow, Russian Federation

Abstract

Purpose To describe a new technique for removing residual cortical material adjacent to posterior lens capsule during cataract surgery with the help of cohesive ophthalmic viscosurgical devices. Methods In this technique, if there are still cortical remnants and lens epithelial cells left after the routine irrigation–aspiration and polishing at the final steps of cataract surgery, the capsule is filled to about one-third with a highly viscous cohesive ophthalmic viscosurgical device. Rinsing is performed from the anterior chamber with the water jet directed tangentially to the ophthalmic viscosurgical device bolus and towards the posterior capsule, which creates a turbulence creating a “grindstone effect”. The ophthalmic viscosurgical device bolus transforms into a ball and starts to rotate very quickly within the capsule, grinding away the cortical remnants. Results In the first series of 62 cases, there were no intra-operative or post-operative complications. At day 1 there was no corneal oedema and no hypertension of intraocular pressure. Visual outcomes were good with a mean best corrected distance visual acuity of −0.01 ± 0.11 logMAR. Conclusion This technique appears to be effective and fast in removing persistent cortical remnants from the surface of the posterior capsule, while minimising risks such as capsule aspiration during irrigation/aspiration. There is limited pressure and mechanical force applied on the capsule; the anterior chamber and the corneal endothelium remain safe since the ophthalmic viscosurgical device stays inside the capsular bag to its high cohesiveness and molecular weight. More data on a larger cohort of patients is planned to confirm these results and evaluate long-term effects on posterior capsule opacification.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3