Continuous Renal Replacement Therapy in Critically Ill Patients: Monitoring Circuit Function

Author:

Holt A. W.1,Bierer P.1,Bersten A. D.1,Bury L. K.1,Vedig A. E.12

Affiliation:

1. Department of Critical Care Medicine, Flinders Medical Centre, Adelaide, South Australia

2. Department Head and Director, Critical Care Medicine Unit.

Abstract

There is currently no universally accepted method to monitor circuit function or guidelines for circuit replacement during continuous renal replacement therapies (CRRT). The objectives of this study were to diagnose the causes of circuit failure, identify factors responsible for circuit clotting and determine a predictive monitor of circuit function. The CRRT technique used in this study was continuous venovenous haemodialysis (CVVHD). Continuous monitoring of circuit pressures (pre- and post-haemofilter and their difference: the transfilter pressure gradient) was used to diagnose the causes of circuit failure. In circuits ceasing due to clotting, the factors thought to contribute, anticoagulation, haematocrit and platelet count, were measured at the commencement of CVVHD and every eight hours thereafter until circuit failure. Monitors of circuit function, creatinine clearance and plasma to diafiltrate urea ratio were measured every eight hours and compared to the transfilter pressure gradient. During a three-month period data was collected on five consecutive patients (41 consecutive haemofilters). Clotting of the haemofilter (63%) and air detection chamber (7.5%) were the most common identifiable causes of circuit failure. The duration of their circuit life was described using multiple regression analysis, i.e. hours of filter life = -82.8 + (Δ platelet count x 0.25) + (Δ haematocrit x 3.6) + (circuit flow [ml/min] x 4) R2 = 0.77. A rise in transfilter pressure gradient and a fall in haemofilter function discriminated clotted filters with falling function (decrease in creatinine clearance and urea ratio) from unclotted filters. In any circuit an increase of 26 mmHg or more in the transfilter pressure gradient accurately predicted circuit failure due to clotting and imminent cessation of function. Increases in platelet count, haematocrit, and low circuit flows are important determinants of haemofilter life. The measurement of transfilter pressure gradient across the haemofilter is an accurate bedside monitor of circuit function.

Publisher

SAGE Publications

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3