Discordance between ROTEM® clotting time and conventional tests during unfractionated heparin–based anticoagulation in intensive care patients on extracorporeal membrane oxygenation

Author:

Prakash S.1,Wiersema U. F.1,Bihari S.1,Roxby D.2

Affiliation:

1. Department of Intensive Care, Flinders Medical Centre, Bedford Park, South Australia

2. SA Pathology Transfusion Medicine, Flinders Medical Centre, Bedford Park, South Australia

Abstract

We hypothesised that ROTEM® (Basel, Switzerland) INTEM® (ROTEM, Basel, Switzerland) clotting time (CT) would have good agreement with activated partial thromboplastin time (aPTT) in determining whether a dose adjustment should be made to the unfractionated heparin (UFH) infusion in patients on extracorporeal membrane oxygenation. All patients treated with extracorporeal membrane oxygenation over a five-year period were included for data analysis. Retrospective analysis was performed of prospectively collected data points, wherein aPTT, activated CT and ROTEM was performed simultaneously to monitor UFH–based anticoagulation. Two hundred data points were available for analysis. Turnaround time was shortest for activated CT followed by ROTEM and aPTT. Despite achieving therapeutic aPTT targets, the majority (>50%) of INTEM CT results were within normal limits. The aPTT and INTEM CT results correlated weakly (r=0.31, 95% confidence interval [0.17, 0.43]) and there was no agreement between the directional changes of aPTT and INTEM CT results on successive days (χ2 = 2.33, P=0.17). Due to relative insensitivity, INTEM CT–guided UFH titration was estimated to result in a 289% increase in incidence of up-titration, over aPTT–guided titration. The INTEM CT results (r=0.36, 95% confidence interval [0.23, 0.48]) correlated weakly with UFH infusion rates. The UFH infusion rate only explained 13% variability in INTEM CT values. While haemorrhagic complications were frequent, no major clotting complications were encountered. Our results demonstrated that aPTT and INTEM CT do not provide equivalent information to guide UFH infusion rate titration during extracorporeal membrane oxygenation. Our study suggests caution regarding the use of ROTEM for guiding UFH–based anticoagulation as it may lead to excessive UFH exposure.

Publisher

SAGE Publications

Subject

Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3