Affiliation:
1. School of Physiotherapy, Faculty of Health Sciences, The University of Sydney, N.S.W., Australia
Abstract
Manual hyperinflation (MHI) is used by physiotherapists as a treatment technique in intubated patients. This study investigated the effect of three different MHI techniques using a Mapleson-C circuit configuration with a CIG Medishield valve on volume delivered (Vt), peak inspiratory (PIFR) and expiratory flow rates (PEFR), and peak airway pressure (PAP) in a test lung model. The protocols differed in the degree of valve closure and inclusion of an inspiratory pause. For protocols 1, 2 and 3 the measures were Vt—1.33 (0.21), 2.74 (0.13), 3.55 (0.12) litres; PAP— 14.30 (0.82), 24.00 (0.47), 30.20 (0.92) cmH 2 O and PIFR—1.13 (0.05), 1.51 (0.15), 1.32 (0.09) l/s respectively. All pair comparisons were statistically significant except for PEFR (l/s), which was significantly lower for protocol 1 [1.62 (0.06)], compared to protocols 2 [2.01 (0.25)] and 3 [2.10 (0.19)] but not between protocols 2 and 3. Circuit and technique choice should be considered in relation to the specific therapeutic aim of treatment.
Subject
Anesthesiology and Pain Medicine,Critical Care and Intensive Care Medicine
Cited by
15 articles.
订阅此论文施引文献