Clinical Features Associated with ‘Normal Range’ Fibrin D-Dimer Levels in Atrial Fibrillation Patients with Left Atrial Thrombus

Author:

Bai Ying1ORCID,Luo Si-Qing2,Liu Si-Tong1,Gong Ling1,Zhong Peng3,Wang Zhen-Zhou4,Lip Gregory YH56,Zou Yi-Xi7,Guo Wei-Hua2

Affiliation:

1. Cardiovascular Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China

2. Dongzhimen Hospital, Beijing University of Chinese Medicine, Beijing, China

3. Department of Ultrasound, Beijing Friendship Hospital, Capital Medical University, Beijing, China

4. Trauma Medicine Center, Peking University People's Hospital, Beijing, China

5. Liverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, UK

6. Department of Clinical Medicine, Aalborg University, Aalborg, Denmark

7. Department of Cardiac Surgery, Beijing Anzhen Hospital, Capital Medical University, Beijing, China

Abstract

Background Left atrial thrombus (LAT) often complicates with atrial fibrillation (AF). The evidence whether fibrin D-dimer levels could be used as a predictive biomarker for LAT is contradictory. This study firstly investigated the relationship between ‘normal range’ D-dimer and prevalent LAT. Second, we explored factors contributing to normal D-dimer levels in the presence of LAT. Methods We studied 244 AF patients with LAT (mean age: 59.9 years, SD:11.7; 53.3% female): of these, 103 (42.2%) had normal D-dimer, 25 (10.2%) had atrial thrombus exclusion score (ATE score) of 0 19 (16.7%) males had CHA2DS2-VASc score of 0, 21(16.2%) females had CHA2DS2-VASc score of 1 and 16 had overlapped ATE score of 0 and CHA2DS2-VASc score of 0 (N = 8 if male) or CHA2DS2-VASc score of 1(N = 8 if female). Using multivariate binary analysis, larger left atrial diameter (LAD; adjusted OR: 1.06, 1.03−1.10, p = 0.001) were associated with increased D-dimer. Patients with high body mass index (BMI), hypertension history and previous anticoagulation were more likely to show normal range D-dimer levels in the presence of LAT. Conclusions A high prevalence (42.2%) of ‘normal range’ D-dimer levels was found in AF patients with LAT, especially in those with hypertension, high BMI and prior anticoagulation. D-dimer levels of those patients with larger LAD were more likely to be increased.

Publisher

SAGE Publications

Subject

Hematology,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3