A technical note on intra-arterial cone-beam computed tomography for the evaluation of flow-diverter stents: Image quality differences between diluted and non-diluted contrast medium

Author:

Kocer Naci1,Kandemirli Sedat G12ORCID,Ruijters Daniel3,Mantatzis Michalis4,Kizilkilic Osman1ORCID,Islak Civan1

Affiliation:

1. Division of Neuroradiology, Department of Radiology, Cerrahapasa Medical Faculty, Istanbul University, Istanbul, Turkey

2. Department of Radiology, University of Iowa Hospitals and Clinics, Iowa City, IA, USA

3. Philips Healthcare, Image Guided Therapy Systems Innovation, Best, the Netherlands

4. Division of Neuroradiology, Department of Radiology, Democritus University of Thrace, Komotini, Greece

Abstract

Background Design of flow-diverter stents for flexibility, tractability, and low profile limits their radiopacity on conventional digital subtraction angiography. Cone-beam computed tomography (CBCT) offers higher spatial resolution for the evaluation of flow-diverter stents. However, CBCT requires optimal dilution and timing of contrast medium for simultaneous visualization of the stent, arterial lumen, and vessel wall. There are only limited data on the effects of different contrast dilutions on CBCT image quality in neurointerventional applications. Materials and methods In our institution, intra-arterial CBCTs were acquired during stent deployment and at follow-ups with 10% diluted contrast. We had recently started acquiring intra-arterial CBCTs with non-diluted contrast. Retrospective analysis of our flow-diverter data identified eight cases with different aneurysm locations who had intra-arterial CBCT with 10% diluted contrast immediately after flow-diverter stent deployment and with non-diluted contrast technique during follow-ups. For each case, the image quality between diluted and non-diluted contrast techniques was compared qualitatively by assessing stent visualization and quantitatively by plotting gray-scale intensity values along the vessel lumen. Results In two sets of CBCT images per each case, there was no substantial difference between diluted and non-diluted CBTC techniques for the evaluation of stent architecture and lumen opacification. Gray-scale intensity values perpendicular to the lumen revealed similar intensity values along the neighboring parenchyma, vessel wall, and lumen for the two different contrast techniques. Conclusion Intra-arterial CBCT angiography can be performed without contrast dilution and still achieve adequate image quality in certain cerebral aneurysms treated with flow diverter. The non-diluted contrast technique avoids the time loss during preparation of diluted contrast and installation of diluted contrast to the injector in angiography suites with a single power injector.

Publisher

SAGE Publications

Subject

Immunology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3