Image quality assessment in low-dose COVID-19 chest CT examinations

Author:

Feghali Joelle A1ORCID,Russo Roberta A1,Mamou Adel1,Lorentz Axel1,Cantarinha Alfredo1,Bellin Marie-France123,Meyrignac Olivier123

Affiliation:

1. Diagnostic and Interventional Radiology Department, AP-HP Paris Saclay University, Bicêtre Hospital, Le Kremlin-Bicêtre, Le Kremlin Bicêtre, France

2. Faculty of Medicine, Paris-Saclay University, Le Kremlin-Bicêtre, France

3. Laboratoire d'Imagerie Biomédicale Multimodale (BioMaps), Université Paris-Saclay, CEA, CNRS, Inserm, Service Hospitalier Frédéric Joliot, Orsay, France

Abstract

Background Low-dose thoracic protocols were developed massively during the COVID-19 outbreak. Purpose To study the impact on image quality (IQ) and the diagnosis reliability of COVID-19 low-dose chest computed tomography (CT) protocols. Material and Methods COVID-19 low-dose protocols were implemented on third- and second-generation CT scanners considering two body mass index (BMI) subgroups (<25 kg/m2 and >25 kg/m2). Contrast-to-noise ratios (CNR) were compared with a Catphan phantom. Next, two radiologists retrospectively assessed IQ for 243 CT patients using a 5-point Linkert scale for general IQ and diagnostic criteria. Kappa score and Wilcoxon rank sum tests were used to compare IQ score and CTDIvol between radiologists, protocols, and scanner models. Results In vitro analysis of Catphan inserts showed in majority significantly decreased CNR for the low dose versus standard acquisition protocols on both CT scanners. However, in vivo, there was no impact on the diagnosis: sensitivity and specificity were ≥0.8 for all protocols and CT scanners. The third-generation scanner involved a significantly lower dose compared to the second-generation scanner (CTDIvol of 1.8 vs. 2.6 mGy for BMI <25 kg/m2 and 3.3 vs. 4.6 mGy for BMI >25 kg/m2). Still, the third-generation scanner showed a significantly higher IQ with the low-dose protocol compared to the second-generation scanner (30.9 vs. 28.1 for BMI <25 kg/m2 and 29.9 vs. 27.8 for BMI >25 kg/m2). Finally, the two radiologists had good global inter-reader agreement (kappa ≥0.6) for general IQ. Conclusion Low-dose protocols provided sufficient IQ independently of BMI subgroups and CT models without any impact on diagnosis reliability.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3