Tissue perfusion of the kurtosis/diffusion mismatch differs from the central core and peripheral regions in acute cerebral infarction patients

Author:

Sun Haizhen12,Wu Yalin3,Liu Na3,Long Miaomiao4,Liu Guoping5,Sun Phillip Zhe67,Yin Jianzhong4ORCID

Affiliation:

1. Department of Radiology, Tianjin Medical University Chu Hsien-I Memorial Hospital & Tianjin Institute of Endocrinology, Tianjin, PR China

2. NHC Key Laboratory of Hormones and Development (Tianjin Medical University), Tianjin Key Laboratory of Metabolic Diseases, Tianjin, PR China

3. The First Central Clinical College of Tianjin Medical University, Tianjin, PR China

4. Department of Radiology, Tianjin First Central Hospital, Tianjin Medical Imaging Institution, Tianjin, PR China

5. Department of Neurology, Tianjin First Central Hospital, Tianjin, PR China

6. Yerkes Imaging Center, Yerkes National Primate Research Center, Emory University, Atlanta, GA, USA

7. Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, USA

Abstract

Background Despite its wide adoption in stroke imaging, the diffusion-weighted imaging (DWI) lesion is heterogeneous. The emerging diffusion kurtosis imaging (DKI) has been postulated to resolve the graded DWI lesion. Purpose To determine the perfusion characteristics of the central infarction core, kurtosis/diffusion mismatch, and peripheral regions. Material and Methods Patients with acute ischemic stroke underwent DWI, DKI, and perfusion-weighted imaging (PWI) scans. The patients were divided into mean kurtosis (MK)/mean diffusivity (MD) match and mismatch groups. Perfusion parameters were measured in the MK/MD lesion and peripheral areas in the MK/MD match group. We also analyzed perfusion status in the MK/MD lesion mismatch area for the mismatch group. Results A total of 40 eligible patients (24 MK/MD match and 16 MK/MD mismatch) were enrolled in the final data analysis. The MTT and TTP progressively decreased, while the cerebral blood flow (CBF) and cerebral blood volume (CBV) increased from the central to peripheral areas. In addition, CBF in the MK/MD mismatch region was significantly higher than that in the central region ( P < 0.05), but similar to the peripheral region. Furthermore, CBV in the MK/MD mismatch region did not differ significantly from that of the central region, but both were significantly lower than that of the peripheral area ( P < 0.05). Conclusion The MK/MD mismatch region had blood flow similar to the peripheral region but with a reduced blood volume, indicating that it was less ischemic from the infarction core, albeit insufficient collateral circulation.

Funder

Research Project of Tianjin Public Health Committee

National Natural Science Foundation of China

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Applications of Magnetic Resonance Imaging in Stroke for Multidimensional Assessment;AI and IoT-Based Technologies for Precision Medicine;2023-10-18

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3