Semi-automatic prostatic artery detection using cone-beam CT during prostatic arterial embolization

Author:

Schnapauff Dirk1,Maxeiner Andreas2,Wieners Gero1,Denecke Timm1,Hamm Bernd1,Gebauer Bernhard1,Jonczyk Martin13ORCID

Affiliation:

1. Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Department of Radiology, Berlin Institute of Health, Berlin, Germany

2. Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Department of Urology, Berlin Institute of Health, Berlin, Germany

3. Berlin Institute of Health (BIH), Berlin, Germany

Abstract

Background Due to the broad variability of the prostatic artery (PA), its origin, small calibers, and tortuous courses, prostatic arterial embolization (PAE) is challenging, time-consuming, and results in high radiation doses. Purpose To evaluate the accuracy of PA detection using cone-beam computed tomography (CBCT) performed from the aortic bifurcation in combination with a semi-automatic detection software in comparison to oblique view digital subtraction angiography (DSA) with internal iliac artery (IIA) injection. Material and Methods Twenty-two consecutive patients were included in this retrospective, IRB-approved study between July and December 2017. CBCT from the aorta and 30° oblique-view DSA from both IIAs were obtained for PA detection. Results of suggested PAs from the semi-automatic vessel detection software after CBCT and IIA DSA were compared. Moreover, dose area product (DAP) was recorded. Statistical analysis included Spearman’s correlation, Mann–Whitney U test, and the Wilcoxon test considering P<0.05 as significant. Results PA type was classified significantly better with CBCT compared to DSA ( P=0.047). In IIA DSA, PAs could not be identified in 18% on the left and in 17% on the right side. CBCT detected all PAs, although truncation occurred in 59% because of the limited field of view. Mean DAP of the whole procedure was 257,161.32±127,909.36 mGy*cm2. Mean DAPs were for a single DSA 14,502.51±9,437.67 mGy*cm2 and for one CBCT 15,589.23±2,722.49 mGy*cm2. A mean of 14.82 DSAs and only one CBCT were performed. CBCT accounted for 6% and DSA for 84% of the entire DAP of the procedure. Conclusion CBCT with semi-automatic feeding vessel detection software detects PAs more accurately than IIA DSA and may reduce radiation dose.

Funder

Berlin Institute of Health

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3