Hybrid iterative reconstruction algorithm in brain CT: a radiation dose reduction and image quality assessment study

Author:

Löve Askell1,Siemund Roger1,Höglund Peter2,Van Westen Danielle1,Stenberg Lars1,Petersen Cecilia1,Björkman-Burtscher Isabella M13

Affiliation:

1. Department of Neuroradiology, Skåne University Hospital, Lund University, Lund, Sweden

2. Competence Centre for Clinical Research, Skåne University Hospital, Lund University, Lund, Sweden

3. Lund University Bioimaging Centre, Lund University, Lund, Sweden

Abstract

Background Iterative reconstruction (IR) algorithms improve image quality and allow for radiation dose reduction in CT. Dose reduction is particularly challenging in brain CT where good low-contrast resolution is essential. Ideally, evaluation of image quality combines objective measurements and subjective assessment of clinically relevant quality criteria. Subjective assessment is associated with various pitfalls and biases. Purpose To evaluate the potential of the hybrid IR algorithm iDOSE4 to preserve image quality in phantom and clinical brain CT acquired with 30% reduced radiation dose, and to discuss the image quality assessment methods. Material and Methods Forty patients underwent two consecutive brain CTs with normal radiation dose (ND) and 30% reduced dose (RD). Both ND and RD were reconstructed with FBP. In addition the reduced dose CTs were reconstructed with two levels of IR (ID2, ID4). Three image quality criteria (grey-white-matter discrimination, basal ganglia delineation, general image quality) were graded and ranked by six neuroradiologists. Noise levels and contrast-to-noise ratios (CNR) were measured in clinical data. Noise, signal-to-noise ratio (SNR), spatial resolution, and noise-power spectrum (NPS) were also assessed in a phantom. Results Subjective image quality was considered adequate for clinical use for all reconstructions, graded good or excellent in 93% of cases for ND, 83% for ID4, 79% for ID2, and 67% for RD. For all quality parameters, ID4 and ID2 were graded better than RD ( P < 0.0055 and P < 0.035), but worse than ND ( P < 0.001). In clinical images, objective measurements showed lower noise and significantly higher CNR in ID4 compared with ND and RD ( P < 0.001). CNR was similar for ID2 and ND. In the phantom, IR reduced noise while maintaining spatial resolution and NPS. Conclusion: The IR algorithm improves image quality of reduced dose CTs and consistently delivers sufficient image quality for clinical purposes. Pitfalls related to subjective assessment can be addressed with careful study design.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3