Abstract

Background Computed tomography (CT) is widely used not only for diagnostic purposes but also for image guidance during different types of interventions. Therefore, radiation exposure of both patients and interventional radiologists remains a much-discussed topic. Purpose To quantify radiation exposure of interventional radiologists during multiple CT-guided interventions using dosimeters placed under and outside standard protective lead clothing. Material and Methods A total of 113 consecutive interventions covering three different types of procedures (grouped as periradicular infiltration therapy, biopsies, and drain placement) and performed using routine clinical protocols were prospectively analyzed. The interventions were performed by two radiologists of different experience levels with identically placed dosimeters outside and underneath their protective clothing. Personal doses (right hand, eye lens, thyroid gland, thorax, gonads) were cumulatively measured for each type of intervention and separately for the two radiologists. Results Personal dose was below the detection limit of the dosimeters during periradicular infiltration therapy. In the biopsy and drain placement groups, the highest dose was found for the right hand (maximum cumulative dose = 1.84 ± 1.30 mSv in 19 consecutive drain placements). Under the protective gear, exposure was only observed for drain placements performed by the less experienced radiologist (maximum = 0.05 ± 0.04 mSv for the eye lens). Conclusion Personal doses measured here were far below annual thresholds published by the International Commission on Radiological Protection. Therefore, performing multiple CT-guided interventions appears to be safe for interventional radiologists in terms of radiation exposure.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3