CO2-based C-arm computed tomography (CACT) of the pelvic arteries: feasibility and diagnostic performance in comparison to CO2-angiography in patients with peripheral arterial disease

Author:

S Becker Lena1ORCID,Dewald Cornelia LA1,Maschke Sabine K1,Werncke Thomas1,Meyer Bernhard C1,Wacker Frank K1,Hinrichs Jan B1ORCID

Affiliation:

1. Institute for Diagnostic and Interventional Radiology, Medical School Hannover, Germany

Abstract

Background Patients with substantially impaired kidney function and peripheral arterial disease (PAD) underwent comparative CO2-based depiction of the pelvic arteries (PAs). Purpose To evaluate the feasibility and diagnostic performance of CO2-based C-arm computed tomography (CACT) and compare its depiction of PAs with CO2-digital subtraction angiography (DSA). Material and Methods Fifteen patients (10 men, mean age 70 ± 11 years) with PAD received CO2-DSA and CO2-CACT of the PAs, depicted from the aorta to femoral arteries. These were divided into nine segments (135 in total) and graded by two independent readers for image quality (IQ; 1 = sufficient, 2 = minimal impairments, 3 = insufficient, 4 = outside field of view) and subsequent stenosis grading (SG; grade 1: normal to grade 4: occlusion), under exclusion of all segments with insufficient IQ. Inter-observer and inter-modality agreement calculation and subsequent consensus reading were performed and correlated to a standard of reference (StOR), representing a modality consensus. Results Of 135 segments, 117 showed sufficient IQ, excluding 18 segments (10 CACT, 8 DSA). Inter-observer agreement for IQ and consecutive SG demonstrated good to excellent agreement: IQDSA: κ = 0.83, IQCACT: κ = 0.76; StenosisDSA: κ = 0.71, StenosisCACT: κ = 0.84. Inter-modality agreement for SG lay at κ = 0.76 and κ = 0.65, respectively. More stenoses could be detected by CACT, and analysis of pooled consensus values of SG in CACTcons versus StOR showed an excellent agreement (κ = 0.96) that proved considerably higher than the moderate agreement between consensus values in DSAcons versus StOR (κ = 0.43). Conclusion CO2-CACT proved feasible, and has the potential to optimize angiographic work-up of PAD in patients with contraindications for other contrast media.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3