Visualization of wrist ligaments with 3D and 2D magnetic resonance imaging at 3 Tesla

Author:

Götestrand Simon12ORCID,Björkman Anders34,Björkman-Burtscher Isabella M56,Ab-Fawaz Rana78,Kristiansson Ingvar1,Lundin Björn12,Geijer Mats569ORCID

Affiliation:

1. Department of Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden

2. Department of Radiology, Clinical Sciences, Lund University, Lund, Sweden

3. Department of Translational Medicine – Hand Surgery, Skåne University Hospital, Malmö, Sweden

4. The Wallenberg Center for Molecular Medicine, Lund University, Sweden

5. Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden

6. Department of Clinical Sciences, Lund University, Lund, Sweden

7. Department of Radiology, Kristianstad Hospital, Kristianstad, Sweden

8. European Telemedicine Clinic, Department of Musculoskeletal Radiology, Barcelona, Spain

9. Region Västra Götaland, Sahlgrenska University Hospital, Department of Radiology, Gothenburg, Sweden

Abstract

Background Wrist ligaments are challenging to visualize using magnetic resonance imaging (MRI). Injuries involving the scapholunate ligament (SLL), the lunotriquetral ligament (LTL), and the triangular fibrocartilage complex (TFCC) are common and difficult to diagnose, often requiring diagnostic arthroscopy. Purpose To compare the visualization of wrist ligaments on a three-dimensional (3D) sequence with two-dimensional (2D) sequences on 3-T MRI. Material and Methods Eighteen healthy volunteers were examined with a 3D SPACE (sampling perfection with application optimized contrasts using different flip angle evolution) sequence and 2D coronal, axial, and sagittal proton density-weighted (PD) sequences. Four musculoskeletal radiologists graded the anatomical visibility of the SLL, LTL, TFCC, and the image quality, using five grades in a visual grading characteristics (VGC) evaluation. After Bonferroni correction, a P value ≤0.005 was considered statistically significant. Results The 3D images were graded significantly better than the 2D images in the visualization of the dorsal and palmar parts of the SLL and the LTL. Regarding the TFCC, the 3D images were graded significantly better for visualization of the foveal attachment. 2D imaging was not found significantly superior to 3D imaging in any aspect. Conclusion The 3D SPACE sequence was scored as superior to the 2D sequences at 3 T in the assessment of the SLL, the LTL, and the foveal attachment of the TFCC. Thus, 3D SPACE can replace 2D PD sequences when these ligaments need to be assessed.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3