Roc-Analysisc of Detection Performance by Analogue and Digital Plain Film Systems in Chest Radiography

Author:

Müller R.-D.1,Wähling S.1,Hirche H.2,Voss M.1,Blendl C.3,Gocke C.1,Gocke P.1,Buddenbrock B.1,John V.1,Wiebringhaus R.1,Turowski B.1

Affiliation:

1. Central Radiological Diagnostic Institute, Biometry and Epidemiology, University Hospital

2. Institute of Medical Information, Biometry and Epidemiology, University Hospital

3. Department of Photographic Technology, The Technical School; Essen-Cologne, Germany.

Abstract

Purpose: To compare the performances of 4 imaging systems in the diagnostic radiology of the chest: an asymmetric screen-film combination (a-SFC); a conventional screen-film combination of speed class 200 (SFC); a screen-film combination of speed class 200 with an aluminium lung filter; and digital luminescence radiographs (DLR). Material and Methods: Object detectability studies were carried out using an anthropomorphic chest phantom. The images were obtained under standard exposure conditions at 125 kVp. The detection performance of the various systems was evaluated by receiver operating characteristic (ROC) analysis on the basis of a total of 12 240 observations. Results: In the overall evaluation the a-SFC and the SFC plus lung filter received equally high ratings of 0.878±0.018 and 0.860±0.21, respectively (p>0.05). There was no significant difference between the 200-speed SFC and the storage phosphor radiographs. In the mediastinum all the tested systems were clearly superior to the 200-speed SFC (p<0.05) while in the lung fields the 200-speed SFC received a high rating of 0.866±0.026. The a-SFC had slight advantages over the SFC plus lung filter and the 2 digital imaging modes (p>0.05). Conclusion: The a-SFC and the digital luminescence radiographs provide a significant gain in diagnostic information in the mediastinum without diminishing detail detectability in the lung fields and without additional radiation exposure.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Reference30 articles.

1. A Fully Automated Adaptive Unsharp Masking Technique in Digital Chest Radiograph

2. New chest imaging techniques: a comparison of five analogue and digital methods

3. Physical aspects of photostimulable phosphor computed radiography

4. DIN 6867, part 2: Bildregistrierendes System bestehend aus Röntgenfilm, Verstärkungsfolien und Kassette zur Verwendung in der medizinischen Röntgendiagnostik — Bestimmung der Modulationsübertragungsfunktion, p. 2. Normenausschluss Radiologie (NAR), Beuth Verlag, Berlin 1992.

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献