Diagnostic accuracy of 3D color volume-rendered CT images for peroneal tendon dislocation in patients with acute calcaneal fractures

Author:

Ohashi Kenjirou1,Sanghvi Tina2,El-Khoury Georges Y1,Ahn Joong Mo3,Bennett D Lee1,Geijer Mats4,Inaoka Tsutomu5,Berbaum Kevin1

Affiliation:

1. Department of Radiology, University of Iowa Hospitals and Clinics, Iowa City, IA, USA

2. Department of Radiology, University of Florida, Gainesville, FL, USA

3. Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA, USA

4. Department of Radiology, Center for Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden

5. Department of Radiology, Toho University Sakura Medical Center, Sakura, Japan

Abstract

Background Use of three-dimensional (3D) color volume-rendered (VR) images has been reported to be more time-efficient compared to that of cross-sectional computed tomography (CT) images for the diagnosis of peroneal tendon dislocation. However, the diagnostic performance of this technique has not been studied. Purpose To test diagnostic accuracy of 3D color VR CT images of ankle for peroneal tendon dislocation in patients with acute calcaneal fractures. Material and Methods The study consisted of 121 ankle CT studies from 105 consecutive patients (85 men, 20 women; mean age, 42 years; age range, 16–75 years) with acute calcaneal fractures. Peroneal tendon dislocation was diagnosed on multiplanar CT images by consensus of two experienced musculoskeletal radiologists, which served as the reference standard. Three other musculoskeletal radiologists independently reviewed 3D images alone on a workstation. The readers determined whether or not there was peroneal tendon dislocation using three degrees of certainty (definite, probable, and possible). Diagnostic performance of 3D images for peroneal tendon dislocation was evaluated by calculating the sensitivities, specificities, and area under the receiver-operating characteristic (ROC) curves. Results Forty-eight (40%) out of 121 studies showed peroneal tendon dislocation based on the expert readings using multiplanar reformatted images. Sensitivities/specificities of 3D images measured 0.92/0.81, 0.88/0.90, and 0.81/0.92 for three readers, respectively. The area under the proper binormal ROC curve based on all three readers (0.93, 0.94, and 0.92) measured 0.93 with a 95% confidence interval of 0.89–0.98. Conclusion Diagnostic accuracy of 3D images is comparable to, but not as good as that of MPR images for the diagnosis of peroneal tendon dislocation in patients with acute calcaneal fractures.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3