High resolution in vivo 31P-MRS of the liver: potential advantages in the assessment of non-alcoholic fatty liver disease

Author:

Jeon Min Jeong12,Lee Yunjung2,Ahn Sangdoo3,Lee Chulhyun4,Kim Ok-Hee5,Oh Byung-Chul5,Yu Ungsik6,Kim Hyeonjin127

Affiliation:

1. Department of Biomedical Sciences, Graduate School, Seoul National University, Seoul, Republic of Korea

2. Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea

3. Department of Chemistry, Chung-Ang University, Seoul, Republic of Korea

4. Division of Magnetic Resonance Research, Korea Basic Science Institute, Ochang, Chungbuk, Republic of Korea

5. Lee Gil Ya Cancer and Diabetes Institute, Gachon University, Incheon, Republic of Korea

6. Bioneer, Daejeon, Republic of Korea

7. Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Suwon, Republic of Korea

Abstract

Background Biopsy remains the current gold-standard for assessing non-alcoholic fatty liver disease (NAFLD). To develop a non-invasive means of assessing the disease, 31P magnetic resonance spectroscopy (31P-MRS) has been explored, but the severe spectral overlaps and low signal-to-noise-ratio in 31P-MRS spectra at clinical field strength are clearly limiting factors. Purpose To investigate potential advantages of high resolution in vivo 31P-MRS in assessing NAFLD. Material and Methods The study was conducted at 9.4T in control and carbon tetrachloride (CCl4)-treated rats. Rats were divided according to histopathologic findings into a control group ( n = 15), a non-alcoholic steatohepatitis group ( n = 17), and a cirrhosis group ( n = 12). Data were presented with different reference peaks that are commonly used for peak normalization such as total phosphorous signal, phosphomonoester + phosphodiester (PME + PDE), and nucleotide triphosphate (NTP). Then, multivariate analyses were performed. Results In all spectra PME and PDE were well resolved into phosphoethanolamine (PE) and phosphocholine (PC), and into glycerophosphorylethanolamine (GPE) and glycerophosphorylcholine (GPC), respectively. Those MRS measures quantifiable only in highly resolved spectra had higher correlations with histology than those conventional MRS measures such as PME, PDE, and NTP. The optimized partial least-squares discriminant analysis (PLS-DA) model correctly classified 79% (22/28) of the rats in the training set and correctly predicted 69% (11/16) of the rats in the test set. Conclusion PE, PC, GPE, GPC, and nicotinamide adenine dinucleotide phosphate (NADP) that can be separately quantifiable in highly resolved spectra may further improve the potential efficacy of 31P-MRS in the diagnosis of NAFLD.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3