Author:
Ørjavik O. S.,Orning O. M.,Skrede M.,Andrew E.
Abstract
Iohexol 350 mg I/ml (Omnipaque) was compared with the routine contrast medium meglumine, Na-Ca-metrizoate 370 mg I/ml (Isopaque Coronar) in coronary angiography in 30 patients. A randomized, double blind, cross-over design was employed. Angiographic image quality, ECG, heart rate, aortic blood pressure and adverse reactions were recorded. Excellent image quality was obtained with both media. Except for one single event of hypotension, only few and minor changes in the parameters measured were recorded. No distinct difference between the two media was found. Iohexol seems to be suitable for selective coronary angiography.
Subject
Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献