Noncoplanar Volumetric Modulated Arc Therapy for Hepatocellular Carcinoma Based on a Cage-Like Radiotherapy System: A Simulation Study

Author:

Ma Min1,Niu Chuanmeng1,Li Minghui1,Chen Deqi1,Yan Lingling1,Wang Hongkai1,Dai Jianrong1ORCID

Affiliation:

1. National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China

Abstract

Background The incorporation of noncoplanar beam arrangements has been proposed in liver radiotherapy modalities, which can reduce the dose in normal tissues compared to coplanar techniques. Noncoplanar radiotherapy techniques for hepatocellular carcinoma treatment based on the Linac design have a limited effective arc angle to avoid collisions. Purpose To propose a novel noncoplanar volumetric modulated arc therapy technique based on a cage-like radiotherapy system and investigate its performance in hepatocellular carcinoma patients. Methods The computed tomography was deflected 90° to meet the structure of a cage-like radiotherapy system and design the noncoplanar volumetric modulated arc therapy technique based on a cage-like radiotherapy system plan in the Pinnacle3 planning system. An noncoplanar volumetric modulated arc therapy technique based on a cage-like radiotherapy system plan was customized for each of 10 included hepatocellular carcinoma patients, with 6 dual arcs ranging from −30° to 30°. Six couch angles were set with an interval of 36° and distributed along with the longest diameter of planning target volume. The dosimetric parameters of noncoplanar volumetric modulated arc therapy technique based on a cage-like radiotherapy system plan were compared with the noncoplanar volumetric modulated arc therapy and volumetric modulated arc therapy plan. Results The 3 radiotherapy techniques regarding planning target volume were statistically different for D98%, D2%, conformity index, and homogeneity index with χ2 = 9.692, 14.600, 8.600, and 12.600, and P = .008, .001, .014, and .002, respectively. Further multiple comparisons revealed that noncoplanar volumetric modulated arc therapy technique based on a cage-like radiotherapy system significantly reduced the mean dose ( P = .005) and V5 ( P = .005) of the normal liver, the mean dose ( P = .005) of the stomach, and V30 ( P = .028) of the lung compared to noncoplanar volumetric modulated arc therapy. Noncoplanar volumetric modulated arc therapy technique based on a cage-like radiotherapy system significantly reduced the mean dose ( P = .005) and V5 ( P = .005) of the normal liver, the mean dose ( P = .017) of the spinal cord, V50 ( P = .043) of the duodenum, the maximum dose ( P = .007) of the esophagus, and V30 ( P = .047) of the whole lung compared to volumetric modulated arc therapy. The results indicate that noncoplanar volumetric modulated arc therapy technique based on a cage-like radiotherapy system protects the normal liver, stomach, and lung better than noncoplanar volumetric modulated arc therapy and protects the normal liver, spinal cord, duodenum, esophagus, and lung better than volumetric modulated arc therapy. Conclusions The noncoplanar volumetric modulated arc therapy technique based on a cage-like radiotherapy system technique with the arrangement of noncoplanar arcs provided optimal dosimetric gains compared with noncoplanar volumetric modulated arc therapy and volumetric modulated arc therapy, except for the heart. Noncoplanar volumetric modulated arc therapy technique based on a cage-like radiotherapy system should be considered in more clinically challenging cases.

Funder

National Natural Science Foundation of China

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3