Compressive Stockings After Hindfoot and Ankle Surgery

Author:

Grubhofer Florian1,Catanzaro Sabrina1,Schüpbach Regula1,Imam Mohamed A.123,Wirth Stephan1

Affiliation:

1. Department of Orthopaedics, University of Zurich, Balgrist University Hospital, Zürich, Switzerland

2. Oxford University Hospitals, Oxford, UK

3. Senior Lecturer Suez Canal University, Ismailia, Egypt

Abstract

Background: Swelling and pain are common after foot and ankle procedures. We hypothesized that compressive stockings (CS) treatment after hindfoot surgery would positively influence patient outcomes. Methods: We undertook this randomized controlled trial in 87 consecutive patients to analyze the clinical effect of CS after hindfoot and ankle surgery and evaluate CS-wearing compliance using sensors that were implanted into CS. Ankle swelling, pain status, quality of life (SF-36 score), and the American Orthopaedic Foot & Ankle Score (AOFAS) were set as the primary end points. The CS wearing time in hours and percentage were investigated as the secondary end points. All participants with CS (group I) were informed about the implanted sensor after the CS were taken off. A subgroup analysis of group I was performed to detect differences between patients with high vs low compliance. Results: At 12 weeks, the results of ankle swelling (mean 234 mm in group I and 232 mm in group II), pain in the visual analog scale (1.7 group I vs 1.9 in group II), the SF-36 score (38 points in group I vs 30 points in group II), and the AOFAS score (a mean of 76 points in both groups) showed no statistical differences between the 2 groups. The mean wearing time was 136 (range, 0-470) hours, which corresponds to a compliance rate of 65%. Sixteen participants had high compliance (>80%, >170 hours), and 21 patients had low or noncompliance. The clinical results of patients with high wearing compliance were not significantly better compared to the results of patients with low compliance. Conclusion: CS therapy after ankle and hindfoot surgery was associated with a low wearing compliance and did not influence ankle swelling, function, pain, and the quality of life compared to the control group. Furthermore, the clinical results of patients with high compliance were not better compared to the results of patients with low or noncompliance wearing behavior. Level of Evidence: Level II, prospective randomized study of lower quality.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3