Long-term Follow-up of 254 Ceramic Coated Implant (CCI) Evolution Total Ankle Replacements

Author:

van Es Laurian J. M.12ORCID,van der Plaat Laurens W.3ORCID,Sierevelt Inger N.24,Hoornenborg Daniel2,Haverkamp Daniel2

Affiliation:

1. Department of Orthopedic Surgery, Noordwest Ziekenhuisgroep, Alkmaar, the Netherlands

2. Specilized Centre for Orthopeadic Research & Education (SCORE), Department of Orthopedic Surgery, Xpert Clinics, Amsterdam, the Netherlands

3. Department of Orthopedics and Traumatology, St.-Antonius-Hospital Kleve, Kleve, Germany

4. Department of Orthopedic Surgery, Spaarne Gasthuis Academy, Hoofddorp, the Netherlands

Abstract

Background: The ceramic coated implant (CCI) Evolution was a third-generation implant design used in approximately 2000 total ankle replacements (TARs) between 2003 and 2016. Because this implant was abandoned, long-term follow-up studies are lacking. Methods: All patients undergoing TAR using a CCI prosthesis between 2004 and 2012 were included for analysis. Preoperatively the tibiotalar alignment was measured, and postoperatively the patients were followed up clinically, with radiographs and by questionnaire. The primary outcome was implant survival at 10 years of follow-up. Implant survival was also compared for (1) inflammatory joint disease vs noninflammatory joint disease and (2) preoperative tibiotalar neutral vs varus or valgus alignment. The secondary outcomes were complications, reoperations, and function (assessed by patient-reported outcome measures). Results: Two hundred fifty-four TARs were performed in 237 patients. Two hundred twelve additional procedures were performed to achieve stable ankles. At 10-year follow-up, the survival was 67.5%, with an average time to revision of 4.5 years. The 10-year survival of the inflammatory joint disease group was 76.8% and of the noninflammatory joint group 63.1% ( P = .44). In 248 TARs, the preoperative tibiotalar alignment was measured; (62% neutral, 25% varus, and 13% valgus), these showed 10-year survival rates of 74.7%, 48.2%, and 68.9% respectively ( P = .07). The complication rate was 54%; 37% of patients underwent reoperation. At a mean of 8.5 years, postoperative satisfaction scored an average of 7.0 (SD 2.26) on a 0- to 10-point numeric rating scale. The mean Foot and Ankle Ability Measure sports subscore was 24.7, the mean Foot and Ankle Outcome Score (FAOS) sports subscore was 42.8, and the mean 36-Item Short Form Health Survey score was 40.0. Regarding daily activities, the mean FAOS was 81.0. Conclusion: This is currently the sole study reporting the long-term results of the CCI prosthesis. The survival and functional outcomes were inferior to other third-generation mobile-bearing ankle implants.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Reference43 articles.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3