Abstract

Background: The initial ultimate load for graft fixation is one of the essential factors in the reconstruction of lateral ankle ligaments. Several anchoring devices have been developed to fix the substitute ligament into the bone. A fair comparison of these fixation methods warrant a reproducible examination system. The purpose of this study was to make an experimental animal model and to compare the initial ultimate loads of 3 graft fixation methods, including the use of EndoButton (EB), interference screw (IFS), and a novel socket anchoring (SA) technique. Methods: Porcine calcaneus bones and 5-mm-wide split bovine Achilles tendons were used as fixation bases and graft materials, respectively. Both ends were firmly sutured side-by-side, using the circumferential ligation technique as a double-strand substitute that was 45 mm in length. Porcine calcanei with similar characteristics to adult human calcanei were mounted on a tensile testing machine, and substitutes were fixed into bones using the 3 fixation methods. A polyester tape was passed through the tendon loop and connected to a crosshead jig of the testing machine. The initial ultimate loads were measured in 15 specimens for each fixation method to simulate a lateral ankle ligament (LAL) injury. Results: The ultimate loads (ULs) were 223.6 ± 52.7 N for EB, 229.7 ± 39.7 N for SA, and 208.8 ± 65.3 N for IFS. No statistically significant difference was observed among the 3 groups ( P = .571). All failures occurred at the bone–ligament substitute interface. Conclusion: The initial ULs in all 3 fixation methods were sufficient for clinical usage. These values were larger than the UL of the anterior talofibular ligament; however, these were smaller than the UL of the calcaneofibular ligament. Clinical Relevance: In an experimental animal model, ULs for SA, EB, and IFS techniques showed no significant difference. All failures were observed in the fixation site of the calcaneus and were overwhelmingly related to suture fixation failure.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3