A Comparison Study of Plantar Foot Pressure in a Standardized Shoe, Total Contact Cast, and Prefabricated Pneumatic Walking Brace

Author:

Baumhauer J.F.1,Wervey R.2,McWilliams J.3,Harris G.F.4,Shereff M.J.5

Affiliation:

1. Assistant Professor of Orthopaedic Surgery, Box 665, 601 Elmwood Avenue, University of Rochester Medical Center, Rochester, New York 14642.

2. Graduate Student, Marquette University, Milwaukee, Wisconsin 53226.

3. Orthopaedic Resident, Medical College of Wisconsin, Milwaukee, Wisconsin 53226.

4. Orthopaedic Research Professor, Medical College of Wisconsin, Milwaukee, Wisconsin 53226.

5. Associate Professor, Orthopaedic Surgery, Medical College of Wisconsin, Milwaukee, Wisconsin 53226.

Abstract

Total contact casting is the current recommended treatment for Wagner Stage 1 and 2 neuropathic plantar ulcers. The rationale for this treatment includes the equalization of plantar foot pressures and generalized unweighting of the foot through a total contact fit at the calf. Total contact casting requires meticulous technique and multiple cast applications to avoid complications before ulcer healing. An alternative to total contact casting is the use of a prefabricated brace designed to maintain a total contact fit. This study compares plantar foot pressure metrics in a standardized shoe (SS), total contact cast (TCC), and prefabricated pneumatic walking brace (PPWB). Five plantar foot sensors (Interlink Electronics, Santa Barbara, CA) were placed at the first, third, and fifth metatarsal heads, fifth metatarsal base, and midplantar heel of 10 healthy male subjects. Each subject walked at a constant speed over a distance of 280 meters in a SS, PPWB, and TCC. A custom-made portable microprocessor-based system, with demonstrated accuracy and reliability, was used to acquire the data. No significant differences in peak pressure or contact duration were found between the initial and repeat SS trials ( P > 0.05). Peak pressures were reduced in the PPWB as compared to the SS for all sensor locations ( P < 0.05). Similarly, peak pressures were reduced in the TCC compared to the SS for all sensor locations ( P < 0.05) with the exception of the fifth metatarsal base ( P = 0.45). Our results are summarized as follows: (1) the methods used in the current study were found to be reliable through a test-retest analysis; (2) the PPWB decreased peak plantar foot pressures to an equal or greater degree than the TCC in all tested locations of the forefoot, midfoot, and hindfoot; (3) compared to a SS, contact durations were increased in both the TCC and PPWB for most sensor locations; and (4) the relationship of peak pressure over time, the pressure-time integral, is lower in the brace compared to the shoe at the majority of sensor locations. The values are not significantly different between the cast and shoe. These findings suggest an unweighting of the plantar foot and equalization of plantar foot pressures with both the PPWB and TCC. Based on these findings, the PPWB may be useful in the treatment of neuropathic plantar ulcerations of the foot.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 95 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3