Liquid chromatography–tandem mass spectrometry method for the quantification of a potent H3 receptor antagonist conessine in serum and its application to pharmacokinetic studies

Author:

Shukla Mahendra12,Francis Femi M13,Lal Jawahar12

Affiliation:

1. Pharmacokinetics & Metabolism Division, CSIR-Central Drug Research Institute, Lucknow, India

2. Academy of Scientific and Innovative Research, Mathura Road, New Delhi, India

3. Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research (NIPER), Raebareli, India

Abstract

Conessine, a steroidal alkaloid obtained from the bark and seeds of the plant species of Apocynaceae family, elicits a histamine antagonistic action, selectively for the H3 histaminergic receptors. This alkaloid is used mainly for the treatment of dysentery and helminthic disorders. For the quantification of conessine in serum, a liquid chromatography–tandem mass spectrometry method was developed. Chromatographic separation was achieved on a Zorbax SB-CN column (100 × 4.6 mm, 3.5 µm), and a mobile phase consisting of 90% methanol in aqueous ammonium acetate buffer (pH 3.5) with 0.1% (v/v) formic acid at an isocratic flow rate of 0.6 ml/min at 40℃ provides efficiency in separation. A volume of 40 µl was injected each time and the run time for each sample was 5 min. Phenacetin (internal standard) was added to 50 µl of serum sample prior to liquid–liquid extraction using 3% isopropanol in n-hexane. The detection was performed on a 5500 QTRAP mass spectrometer by multiple reaction monitoring mode via electrospray ionization source. The multiple reaction monitoring of conessine and IS was m/ z 357.4 to m/ z 312.1 and m/ z 180.1 to m/ z 138.1, respectively. The method that showed selectivity and linearity in the range of 1–200 ng/ml was validated in terms of sensitivity, accuracy, precision and stability. The detection and quantitation limits were recognized at 0.1 and 1 ng/ml, respectively. The intra- and inter-day precision and accuracy fulfils the acceptance criteria. Applying the method to the pharmacokinetic studies in rats, conessine showed a peak serum concentration at 2 h post oral dose with a good bioavailability of 71.28 ± 4.65%.

Publisher

SAGE Publications

Subject

Spectroscopy,Atomic and Molecular Physics, and Optics,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3