Shape Loss of Autoclaved, Machine-Bent Cobalt-Chrome and Titanium Spine Surgery Rods

Author:

Willson Rob1,Zhou Haitao2,Fulzele Sadanand1,Mitchell Sean M.3ORCID,Chutkan Norman34

Affiliation:

1. Augusta University, Augusta, GA, USA

2. University of Washington, Seattle, WA, USA

3. University of Arizona, Phoenix, AZ, USA

4. The CORE Institute, Phoenix, AZ, USA

Abstract

Study Design: This was a biomechanical study. Objective: Shape loss of surgical spine rods has been implicated as a factor leading to postsurgical loss of alignment correction. Our objective was to compare the degree of shape loss in surgical spine rods of different compositions under physiological conditions that were bent before or after being autoclaved. Methods: 10 CoCr and 10 commercially pure titanium (CPTi) surgical spine rods were contoured using a machine press. Five CoCr and 5 CPTi rods were bent before being autoclaved (preoperative bent group); 5 CoCr and 5 CPTi rods were bent after being autoclaved (intraoperative bent group). All rods were immersed in a phosphate-buffered saline bath at body temperature (37.2°C ± 2°C). Changes in radius of curvature were measured at different time intervals over an 8-week course using a high-definition scanner. Results: Each rod demonstrated shape loss in radius of curvature (range = 1.04-9.99 mm) over the duration of the study. Intraoperatively bent CPTi rods demonstrated the largest shape loss (range = 8.73-9.99 mm; median 9.33 mm; P < .01). Preoperatively bent CPTi (range = 1.04-1.71 mm; median = 1.39 mm; P < .01) and intraoperatively bent CoCr (range = 1.11-2.11 mm; median = 2.01 mm; P < .01) rods underwent the least amount of shape loss. Conclusion: CPTi spinal rods bent after autoclave may lead to considerable loss of alignment correction. In addition, our results suggest that preautoclave bent CPTi and CoCr spinal rods bent after autoclave may be a more ideal choice of implant because they may provide more resistance to shape loss over time.

Publisher

SAGE Publications

Subject

Neurology (clinical),Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3