Anterior Glenoid Reconstruction With Distal Tibial Allograft: Biomechanical Impact of Fixation and Presence of a Retained Lateral Cortex

Author:

Parada Stephen A.1,Shaw K. Aaron2,McGee-Lawrence Meghan E.3,Kyrkos Judith G.4,Paré Daniel W.5,Amero Jessica5,Going James W.5,Morpeth Brice5,Shelley Robert1,Eichinger Josef K.6,Provencher Matthew T.7

Affiliation:

1. Department of Orthopaedics, Augusta University Medical Center, Augusta, Georgia, USA.

2. Department of Orthopaedic Surgery, Dwight D. Eisenhower Army Medical Center, Augusta, Georgia, USA.

3. Department of Cellular Biology and Anatomy, Department of Orthopaedic Surgery, Medical College of Georgia at Augusta University, Augusta, Georgia, USA.

4. Department of Public Health at Augusta University, Augusta, Georgia, USA.

5. Medical College of Georgia at Augusta University, Augusta, Georgia, USA.

6. Medical University of South Carolina, Charleston, South Carolina, USA.

7. Steadman Philippon Research Institute, Vail, Colorado, USA.

Abstract

Background: Glenoid reconstruction with distal tibial allograft (DTA) is a known surgical option for treating recurrent glenohumeral instability with anterior glenoid bone loss; however, biomechanical analysis has yet to determine how graft variability and fixation options alter the torque of screw insertion and load to failure. Hypothesis: It was hypothesized that retention of the lateral cortex of the DTA graft and the presence of a washer with the screw will significantly increase the maximum screw placement torque as well as the load to failure. Study Design: Controlled laboratory study. Methods: Whole, fresh distal tibias were used to harvest 28 DTA grafts, half of which had the lateral cortex removed and half of which had the lateral cortex intact. The grafts were secured to polyurethane solid foam blocks with a 2-mm epoxy laminate to simulate a glenoid with an intact posterior glenoid cortex. Grafts underwent fixation with 4.0-mm cannulated drills, and screws and washers were used for half of each group of grafts while screws alone were used for the other half, creating 4 equal groups of 7 samples each. A digital torque-measuring screwdriver recorded peak torque for screw insertion. Constructs were then tested in compression with a uniaxial materials testing system and loaded in displacement control at 100 mm/min until at least 3 mm of displacement occurred. Ultimate load was defined as the load sustained at clinical failure. Results: The use of a washer significantly improved the ultimate torque that could be applied to the screws (+cortex and +washer = 12.42 N·m [SE, 0.82]; –cortex and +washer = 10.54 N·m [SE, 0.59]) ( P < .0001), whereas the presence of the native bone cortex did not have a significant effect (+cortex and –washer = 7.83 N·m [SE, 0.40]; –cortex and –washer = 8.03 N·m [SE, 0.56]) ( P = .181). Conclusion: In a hybrid construct of fresh cadaveric DTA grafts secured to a foam block glenoid model, the addition of washers was more effective than the retention of the lateral distal tibial cortex for both load to failure and peak torque during screw insertion. Clinical Relevance: This biomechanical study is relevant to the surgeon when choosing a graft and selecting fixation options during glenoid reconstruction with a DTA graft.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3