Abstract

Background: Despite the increased popularity of reverse total shoulder arthroplasty, total shoulder arthroplasty is the standard treatment for advanced shoulder arthritis in young adult patients. Conventional metal-backed glenoid (MBG) designs result in more loosening and revision surgery compared with cemented polyethylene glenoid components. However, modern MBG designs have been recently devised to overcome such drawbacks. Purpose: To compare the radiolucency, loosening, and failure rates of modern MBG designs with those of conventional designs. Study Design: Systematic review; Level of evidence, 4. Methods: A search for relevant articles was carried out using the PubMed, Cochrane Library, and Embase databases using MeSH (Medical Subject Headings) terms and natural keywords. A total of 362 articles were screened. We descriptively analyzed numerical data between the groups and statistically analyzed categorical data, such as the presence of loosening, failure, and revision surgery. The main outcome was the rate of revision surgery or failure. Subgroup analysis according to follow-up duration was performed to reduce heterogeneity. Results: A total of 25 articles (2036 shoulders) were included; 15 articles (1579 shoulders) involved a conventional MBG design, and 10 (457 shoulders) involved a modern design. The mean age of the patients was 64.2 and 66.5 years in the conventional and modern design groups, respectively, with a mean follow-up duration of 102.0 and 56.1 months, a mean gain of forward elevation of 35.1° and 61.7°, and a mean gain of external rotation of 24.2° and 39.2°. The rate of radiolucency was 48.0% and 16.7%, the rate of loosening was 11.2% and 4.9%, and the rate of revision was 15.9% and 2.4%, for the conventional and modern design groups, respectively. Subgroup analysis according to follow-up duration showed that the rates of loosening and revision were significantly lower in the modern design group ( P < .001). Conclusion: Our findings suggest that modern MBG designs showed significantly lower loosening and failure rates than conventional designs. The overall results of the comparison, including loosening, failure, change in range of motion, and clinical scores, indicate that modern MBG designs are promising. More long-term follow-up studies on modern MBGs should be conducted.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine