Variability Between Full-Length Lateral Radiographs and Standard Short Knee Radiographs When Evaluating Posterior Tibial Slope in Revision ACL Patients

Author:

Mansour Alfred A.1,Steward Joshua1,Warth Ryan J.1,Haidar Layla A.1,Aboulafia Alexis1,Lowe Walter R.1

Affiliation:

1. Department of Orthopedic Surgery, McGovern Medical School, University of Texas Health Science Center at Houston, Houston, Texas, USA

Abstract

Background: Increased posterior tibial slope (PTS) has been identified as a risk factor for failure after anterior cruciate ligament (ACL) reconstruction. Correction of PTS may improve outcomes after revision ACL reconstruction. There are conflicting reports demonstrating the measurement of the PTS on standard short knee (SSK) radiographs versus full-length lateral (FLL) radiographs including the entire tibia. Purpose/Hypothesis: To compare PTS measurements between SSK and FLL radiographs in patients who failed primary ACL reconstruction. It was hypothesized that there would be high variability between the SSK and FLL radiographic measurements. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: The medial and lateral PTS were measured on the SSK and FLL radiographs of 33 patients with failed primary ACL reconstructions. All measurements were performed by 2 trained independent observers (A.A.M., J.S.), and inter- and intraobserver reliability were calculated using the intraclass correlation coefficient (ICC). Measurements recorded by the observer with the higher intraobserver ICC were used for comparison of the PTS on SSK versus FLL radiographs. Results: Both the inter- and the intraobserver reliability values of the PTS measurements were excellent. There was a significant difference in mean PTS on the medial plateau as measured on the SSK and FLL radiographs (11.2°± 5.3° vs 12.5°± 4.6°; P = .03), with the FLL radiographs demonstrating higher PTS. There was also a significant difference in the mean PTS on the lateral plateau as measured on SSK versus FLL radiographs (10.7°± 4.3° vs 12.2°± 4°, respectively; P = .01), with the FLL radiographs demonstrating higher PTS. Notably, 66.67% of the absolute measurements for PTS on the medial plateau differed by ≥2°, with variability as high as 8.5°. Conclusion: Results indicated that FLL and SSK radiographs are not interchangeable measurements for PTS associated with failed ACL reconstruction. Because FLL radiographs demonstrate less variability than SSK radiographs, we recommend obtaining them to evaluate these complex patients.

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3