Detection of grouting defects in prestressed tendon ducts using distributed fiber optic sensors

Author:

Gong Shilin1,Feng Xin12ORCID

Affiliation:

1. State Key Laboratory of Coastal and Offshore Engineering, Dalian University of Technology, Dalian, China

2. Key Laboratory of Engineering Disaster Prevention & Mitigation of Liaoning Province, Dalian University of Technology, Dalian, China

Abstract

To compensate for the shortcomings of the existing point detection methods for grouting defects in prestressed tendon ducts, such as low detection efficiency, stringent detection environment, and easy omission of grouting defects, this article presents a distributed detection approach to detect the grouting defects in tendon ducts. The main objective of the research pertained to the development of a method for accurate identification and location of grouting defects and qualitative evaluation of the size of grouting defects using distributed fiber optic sensors with active heating. Using the thermal analysis of grouting defects in the tendon duct and the research on distributed fiber optic sensors measurement characteristics, our work proposed a method for identifying and locating grouting defects and explored the effect of the grouting defect length and the grouting compactness on the temperature rise of distributed fiber optic sensors. The feasibility of the proposed approach is evaluated through an experimental program. The experimental program involved use of heating distributed fiber optic sensors for the distributed measurement of temperature after the heating and detection of grouting defects in tendon ducts in a concrete beam. The results indicate that distributed fiber optic sensors can monitor the temperature distribution of the tendon duct during a temperature rise in real time. Grouting defects in the tendon duct can be quickly detected and located by identifying temperature anomalies in the temperature contour of the distributed fiber optic sensors. Furthermore, there is a linear relationship between the defect length and the abnormal temperature length on the distributed fiber optic sensors, and the defect length can be identified based on the abnormal temperature length obtained by the measurement. Plane-equivalent thermal conductivity can be used to evaluate the grouting compactness of the tendon duct. When the grouting compactness is greater than 70%, the smaller the plane-equivalent thermal conductivity is, the lower the grouting compactness is. The plane-equivalent thermal conductivity is basically the same when the grouting compactness is less than 70%.

Funder

Transportation Industry R&D Funding of Highway Bridge Diagnosis and Treatment Technique of China

Publisher

SAGE Publications

Subject

Mechanical Engineering,Biophysics

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3