Effects of plate contouring quality on the biomechanical performance of high tibial osteotomy fixation: A parametric finite element study

Author:

Hayatbakhsh Zahra1,Farahmand Farzam2ORCID

Affiliation:

1. Department of Biomedical Engineering, Science and Research branch, Islamic Azad University, Tehran, Iran

2. Mechanical Engineering Department, Sharif University of Technology, Tehran, Iran

Abstract

Locking plates have threaded holes, in which threaded-head screws are affixed. Hence, they do not need to be in intimate contact with underlying bone to provide fixation. There are, however, reports that a large distance between the plate and the bone might cause clinical complications such as delayed union or nonunion, screw pull out, and screw and plate breakage. Considering the diversity in the capabilities and costs of different plate customization techniques, the purpose of this study was to investigate the effect of the plate contouring quality on the biomechanical performance of high tibial osteotomy (HTO) fixation. A finite element model of proximal tibia was developed in Abaqus, using the QCT data of a cadaver. The model was then subjected to open-wedge HTO (correction angle 12°) with TomoFix plate fixation. The sagittal curvature of the plate was changed parametrically to provide certain levels of geometrical fit, and the biomechanical performance parameters of fixation were assessed. Results indicated 5%, 9% and 38% increase in the stiffness of the construct, and the von Mises stress in the plate and locking screw just above the osteotomy site, respectively, when the level of fit of plate changed from 0% (initial non-contoured initial shape) to 100% (fully adapted shape). The same change decreased the pressure at the lateral hinge of the osteotomy by 61%, and the mean of the tensile stress on the screw shaft by 12%. It was concluded that the level of fit has conflicting effects on the biomechanical parameters of the HTO fixation system, that is, the structural stiffness, the pressure at the lateral hinge, the stresses in the plate and screws, and the pull out resistance of the screws. In particular, for HTO patients with high quality bone, the optimal level of fit should provide a tradeoff between these parameters.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3